Technical data 

Output:  

 5 x RJ12 sockets (5V, GND und Data) 

Input: 

screw plug for cable to 2,5qmm 

Display: 

none 

Operating voltage: 

5 V= (+/-10%) 

Current: 

max. 100mA 

Protection circuits: 

ESD- and reverse polarity protection 

 
Temperature,operation:  0°C to +50°C  
Air humidity: 

 

10 - 92% (non condensing) 

Dimensions:  

 

housing 90 x 50 x 25mm, mounting plate 120 x 55mm 

Protection class: 

III 

Housing protect.class:    IP20 
 

Conformity 

EN 50090-2-2 
EN 61000-4-2, ESD 
EN 61000-4-3, HF 
EN 61000-4-4, Burst 
EN 61000-4-5, Surge 
EN 61000-6-1, Interference immunity 
EN 61000-6-3, interference radiation 
RoHS 

 

Connection 1-Wire network (input) 

A screw connection for cable cross sections up to 2.5qmm is provided as input. The screw terminal can be 
unplugged to mount the supply cable. For the electrical function only +5V, GND and Data are necessary. 
Additionally a terminal for a 12V cable core is provided, this connection is not used internally. 
 

Pin Assignment Output Sockets (RJ12) and Connection 

The distribution module has 5 outputs with RJ12 sockets. Here 1-Wire cable temperature sensors can be 
connected directly.  
It is not necessary to remove the plugs, because the plugs of the temperature sensors are connected to the  
1-Wire Extension 5 are coordinated. 

 

 
The output sockets (RJ12 Western socket) are assigned as follows   
 
Assignment RJ12 socket: 

not connected 

ground 

1-Wire Data 

1-Wire Data 

+5 V 

not connected 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

w

w

w

.e

s

e

ra

.d

e

 

Summary of Contents for 1-Wire Extension 5

Page 1: ...al temperature measurement 1 Introduction Before you start to install the 1 Wire Extension 5 and put the device into operation please read this manual carefully until the end especially the section of the safety instructions 2 Product Description The 1 Wire Extension 5 is designed as local distributor for 1 Wire temperature sensors with RJ12 connector In combination with the different cable length...

Page 2: ...1000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 Interference immunity EN 61000 6 3 interference radiation RoHS 5 Connection 1 Wire network input A screw connection for cable cross sections up to 2 5qmm is provided as input The screw terminal can be unplugged to mount the supply cable For the electrical function only 5V GND and Data are necessary Additionally a terminal for a 12V cable core is provi...

Page 3: ...0550 0551 VDE 0700 VDE 0711 and VDE 0860 All final or wiring work must be carried out with the power turned off Before opening the device always unplug or make sure that the unit is disconnected from the mains Components modules or devices may only be put into service if they are mounted in a contact proof housing During installation they must not have power applied Tools may only be used on devic...

Page 4: ...ed If defects occur for which the ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic errors in the online offer We are con...

Reviews: