esera automation 1-Wire Extension 5 User Manual Download Page 1

 

 

 

 

 

 

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

 

  11108  V1.0 R1.0  Manual 

Page 1 of 4 

Art.No. 11108 
 

 
 

User Guide 

5-fold distribution module for  

1-Wire Temperature Sensors 

1-Wire Extension 5  

 
 
 

Features 

 

Distributor for 1-Wire Temperature sensors with  

RJ12 connectors 

 

5 outputs for temperature sensors 

 

Housing for wall mounting 

 

Connection via screw plug connector 

 

Improvement of the signal quality through  

additional electronics 

 

Typical areas of application 

 

Temperature monitoring of heat storage tanks 

 

Heating control, building management system and  

air conditioning 

 

Monitoring of frozen goods 

 

Quality assurance 

 

laboratory equipment, scientific devices 

 

Industrial temperature measurement  

 

 

 

 

 

                              

 

Introduction 

Before you start to install the 1-Wire Extension 5 and put the device into operation, please read this manual 
carefully until the end, especially the section of the safety instructions. 
 

Product Description 

The 1-Wire Extension 5 is designed as local distributor for 1-Wire temperature sensors with RJ12 connector. 
In combination with the different cable lengths of the temperature sensors a simple and fast cabling of up to 
5 temperature sensors is possible, e.g. in the area of a heating system or industrial plant.  
The design of the outputs with RJ12 sockets eliminates errors compared to distributors with clamp 
connections or "luster terminals". 
The cable temperature sensors and the 1-Wire Extension 5 form a coordinated cabling system. 
As further system components for the 1-Wire network, we recommend the use of a 

1-Wire Hub II

 as power 

supply, 

1-Wire bus coupler

 or 

1

-Wire Controller

 1

 as coupling to the control computer. 

No software is required for this module. 
 
 

Illustration similar ,module without LED displays

 

Summary of Contents for 1-Wire Extension 5

Page 1: ...al temperature measurement 1 Introduction Before you start to install the 1 Wire Extension 5 and put the device into operation please read this manual carefully until the end especially the section of the safety instructions 2 Product Description The 1 Wire Extension 5 is designed as local distributor for 1 Wire temperature sensors with RJ12 connector In combination with the different cable length...

Page 2: ...1000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 Interference immunity EN 61000 6 3 interference radiation RoHS 5 Connection 1 Wire network input A screw connection for cable cross sections up to 2 5qmm is provided as input The screw terminal can be unplugged to mount the supply cable For the electrical function only 5V GND and Data are necessary Additionally a terminal for a 12V cable core is provi...

Page 3: ...0550 0551 VDE 0700 VDE 0711 and VDE 0860 All final or wiring work must be carried out with the power turned off Before opening the device always unplug or make sure that the unit is disconnected from the mains Components modules or devices may only be put into service if they are mounted in a contact proof housing During installation they must not have power applied Tools may only be used on devic...

Page 4: ...ed If defects occur for which the ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic errors in the online offer We are con...

Reviews: