Data output:
ECHO 0: Error message as numerical value. 0=ok, 1=first command part, 2=second command part, etc.
ECHO 1: Error message in plain text
The command, "set,sys,echo,0 or 1", for the change of the acknowledgement of receipt can be entered via the
"Command" field.
8.7.
1-Wire Controller / 1-Wire Gateway output at system start, ready
After applying the operating voltage, the 1-Wire Controller / 1-Wire Gateway starts automatically. A successful
system start is indicated by the 1-Wire Controller / 1-Wire Gateway with the output "RDY|0".
The 1-Wire Controller / 1-Wire Gateway also signals that it is ready for operation by 3 flashes of the data LED.
Data can then be read or commands can be entered.
If a debug output is activated, a list of the 1-Wire Controller / 1-Wire Gateway settings is output.
Data output:
1_INF|time
1_RDY|0
=> Controller no._RDY|0 = 1-Wire Controller / 1-Wire Gateway is ready