Jumpers and Coding Switches
4.1.6 Selecting the Output Voltage Range (J400-J731)
For each analog channel there are two jumper fields to configure the voltage range. As the jumpers
are closely connected, they will be explained together.
The voltage swing of the A/D-converters is set via jumpers J400...J730. Unipolar and bipolar
operations are selected by means of the three-pin jumper fields J401...J731. For the assignment of
jumpers to the sixteen channels, please refer to the PCB view on page 13. There the channel units
are designated by numbers.
Alternatively, the voltage swing can also be determined by equipping resistors. In that case the
jumpers are not equipped.
Example: Unipolar output voltage 0...+10V
Jumper settings for output voltage ranges
Output voltage range
0...+10V
Output voltage range
±5V
Default setting at
delivery ->
>
Output voltage range
±10V
VME-DAC1612
Manual • Doc. No.: V.1706.21 / Rev. 1.2
Page 23 of 50
2
1
3
2
1
Jx1
Jx0
bipolar output voltage
unipolar output voltage
open:
closed:
voltage swing = 20 V
voltage swing = 10 V
2
1
3
2
1
Jx1
Jx0
2
1
3
2
1
Jx1
Jx0
2
1
3
2
1
Jx1
Jx0
jumper open
jumper closed