AINTENANCE

 

Replacing the filterbag: 

1.

 

Switch-OFF appliance and unplug from outlet. 

2.

 

Remove hose from suction opening. 

3.

 

Lift metal bottom lock and remove front cover. (Fig. 1) 

4.

 

Remove and dispose of spend filterbag. 

5.

 

Take new filterbag and make sure al creases are folded out. (Fig. 2) 

6.

 

Place new filterbag (arrow pointing up) in housing and close with front 
cover and metal bottom lock. 

Replacing the (HEPA) micromotorfilter: 

1.

 

Switch-OFF appliance and unplug from outlet. 

2.

 

Remove hose from suction opening. 

3.

 

Lift metal bottom lock and remove front cover. 

4.

 

Remove and dispose of spend filterbag. 

5.

 

Remove and dispose of spend motorfilter. 

6.

 

Press new filter into destined slots on one side of the housing (Fig. 3,4).  
(Always place new filter with white, smooth side facing motor)

 

7.

 

Press down on other side of the filter, into the slots on the other side of 
the housing (Fig 5,6)

 

8.

 

Place new filterbag in housing and close with front cover and metal 
bottom lock. 

ATTENTION: Never use appliance without paper filterbag and (HEPA) 
micromotorfilter in place. Never re-use spend filterbags. 
Failure to carry out necessary periodic maintenance can significantly reduce 
the lifespan of your appliance! 

 

antistatic-esd-solutions.com • [email protected]

Summary of Contents for MUNTZ 555-ESD-S GS

Page 1: ...antistatic esd solutions antistatic esd solutions com sales antistatic esd solutions com ...

Page 2: ...s against harmful electrostatic discharges Voltage 100V 120V 220 240V 50 60 Hz versions Motor power Max 880W Housing Permanent dissipative material SR 10E7 10E8 ohms Max suction power Max airflow 160 mbar 35 litres sec Max Noise level Approx 72 db Weight appliance only 2 2 kg Dimensions 31 5 x 12 x 18 5 cm LxWxH Diameter accessories 32 mm Detachable cordset Length 3 meters Filter bag capacity Appr...

Page 3: ...e appliance or the plug with wet hands This appliance is not designed nor suitable to collect liquids Do not pull or carry the appliance by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Keep cord away from hot surfaces Never use appliance with damaged cord or plug Never leave appliance plugged in when left unattended If the appliance is not operating pro...

Page 4: ...t ashes or matches When using the blower function use safety glasses and facial mask Never blow in corners and or in the direction of sharp objects e g staples needles pins or glass fragments Never use appliance without a filter bag and motor exit filters in place Never re use filter bags Repairs must only be performed by an authorized service agent in accordance with national and local safety reg...

Page 5: ...ttachment onto the free hose end optional 3 Press ON OFF switch in OFF position Insert plug into electrical outlet and turn on appliance by pressing ON OFF switch in ON position Operating instructions using blower function 1 Press hose end of the blow assembly into air exit opening 2 Place switch in OFF position and turn power knob to medium setting 3 Insert plug into electrical outlet and turn on...

Page 6: ...m lock and remove front cover 4 Remove and dispose of spend filterbag 5 Remove and dispose of spend motorfilter 6 Press new filter into destined slots on one side of the housing Fig 3 4 Always place new filter with white smooth side facing motor 7 Press down on other side of the filter into the slots on the other side of the housing Fig 5 6 8 Place new filterbag in housing and close with front cov...

Page 7: ...1 2 3 4 5 6 antistatic esd solutions com sales antistatic esd solutions com ...

Page 8: ...nd exit filter Replace if clogged 2 4 Check for blockages in hose and nozzles 2 5 Use less air restrictive nozzles or use them at an increased distance from object to be cleaned 2 6 Reduce power setting electronic version With motor sufficiently cooled down appliance allows restart after 15 20 minutes Loss of suction power blow pressure 1 Switch appliance to OFF and unplug from your outlet 2 Check...

Page 9: ... workmanship and material defects MT will either repair or replace the defective product The above warranty shall not apply to any MT appliance that has been modified or has been damaged by negligence misuse accident failure to follow the MT user manual Wear and tear parts as e g hoses accessories and cordset are not covered by above warranty antistatic esd solutions com sales antistatic esd solut...

Page 10: ...NOTES antistatic esd solutions com sales antistatic esd solutions com ...

Page 11: ...NOTES antistatic esd solutions com sales antistatic esd solutions com ...

Page 12: ...ons BVBA Benelux Businesscenter Boomsesteenweg 690 2610 Wilrijk Belgium IBAN BE75 7360 3843 0151 BIC KREDBEBB VAT N BE0678529648 Reg N 0678529648 Tel 32 3 230 19 75 Fax 32 3 230 19 78 web www antistatic esd solutions com email sales antistatic esd solutions com antistatic esd solutions ...