Connector Assignments
5.3 Conductor Connection/Conductor Cross Sections
The following table contains an extract of the technical data of the line connectors.
Interface
24 V Power Supply
Connector type plug component
(Range of articles)
FKCT 2,5/..-ST KMGY
Connection method
spring-cage
connection
Stripping length
10 mm
Conductor cross section solid min. / max.
0.2 mm² / 2.5 mm²
Conductor cross section stranded min. / max.
0.2 mm² / 2.5 mm²
Conductor cross section stranded, with ferrule without plastic sleeve
min./ max.
0.25 mm² / 2.5 mm²
Conductor cross section stranded, with ferrule with plastic sleeve
min. / max.
0.25 mm² / 2.5 mm²
Conductor cross section AWG/kcmil min. / max.
24 / 12
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve, min. / max.
0.5 mm² / 1.0 mm²
Minimum AWG according to UL/CUL
26
Maximum AWG according to UL/CUL
12
1
Technical Data from Phoenix Contact website, printed circuit board connector, plug component
Page 20 of 74
Manual • Doc. No.: E.3022.21 / Rev. 1.9
ECX-EC