ESD CPCI-PS24 Hardware Manual Download Page 4

Safety Instructions

!

When working with CPCI-PS24 follow the instructions below and read the manual carefully to protect 
yourself from injury and the CPCI-PS24 from damage.

!

The device is a built-in component. It is essential to ensure that the device is mounted in a way that can 
not lead to endangering or injury of persons or damage to objects.

!

The device has to be securely installed in the CPCI rack before commissioning.

!

Protect the CPCI-PS24 from dust, moisture and steam. 

!

Protect the CPCI-PS24 from shocks and vibrations.

!

The CPCI-PS24 may become warm during normal use. Always allow adequate ventilation around the 
CPCI-PS24 and use care when handling.

!

Do not operate the CPCI-PS24 adjacent to heat sources and do not expose it to unnecessary thermal 
radiation. Ensure an ambient temperature as specified in the technical data.

!

Do not use damaged or defective cables to connect the CPCI-PS24.

!

Current circuits which are connected to the device have to be sufficiently protected against hazardous 
voltage (SELV according to EN 60950-1).

!

The CPCI-PS24 may only be driven by power supply current circuits, that are contact protected.

!

The input of the unit is not internally fused. An external fuse of 8 A is recommended. 

!

If the installation requirements are different as listed above, please contact the esd support.

Attention !
Electrostatic discharges may cause damage to electronic components. 

To avoid this, please perform the steps described on page 7 

before

 you touch the CPCI-PS24, 

in order to discharge the static electricity from your body.

Qualified Personal

This documentation is directed exclusively towards personal qualified in control and automation engineering. 
The installation and commissioning of the product may only be carried out by qualified personal, which is 
authorized to put devices, systems and electric circuits into operation according to the applicable national 
standards of safety engineering.

Conformity

The CPCI-PS24 is an industrial product and meets the demands of the EU regulations and EMC standards  
printed in the conformity declaration at the end of this manual.

Warning:

In   a   residential,   commercial   or   light   industrial   environment   the  CPCI-PS24  may  cause   radio 
interferences in which case the user may be required to take adequate measures.

Intended Use

The intended use of the CPCI-PS24 is the operation as 24 V-power supply module in a CPCI system. 
The   guarantee   given   by   esd   does   not   cover   damages   which   result   from   improper   use,   usage   not   in  
accordance with regulations or disregard of safety instructions and warnings.

!

The CPCI-PS24 is intended for installation in a CPCI only.

!

The operation of the CPCI-PS24 in hazardous areas, or areas exposed to potentially explosive materials 
is not permitted.

!

The operation of the CPCI-PS24 for medical purposes is prohibited.

Service Note

The CPCI-PS24 does not contain any parts that require maintenance by the user. The CPCI-PS24 does not 
require any manual configuration of the hardware.

Disposal

Devices which have become defective in the long run have to be disposed in an appropriate way or have to  
be returned to the manufacturer for proper disposal. Please, make a contribution to environmental protection.

Page 4 of 16

Hardware Manual • Doc. No.: I.2301.21 / Rev. 1.0

CPCI-PS24

Summary of Contents for CPCI-PS24

Page 1: ...Manual to Product I 2301 21 CPCI PS24 Hardware Manual Doc No I 2301 21 Rev 1 0 Page 1 of 16 esd electronic system design gmbh Vahrenwalder Str 207 30165 Hannover Germany http www esd eu Phone 49 0 51...

Page 2: ...iability performance or design All rights to this documentation are reserved by esd Distribution to third parties and reproduction of this document in any form whole or in part are subject to esd s wr...

Page 3: ...24 Rev 1 1 Document History The changes in the document listed below affect changes in the hardware as well as changes in the description of the facts only Revision Chapter Changes versus previous ver...

Page 4: ...from your body Qualified Personal This documentation is directed exclusively towards personal qualified in control and automation engineering The installation and commissioning of the product may only...

Page 5: ...l Data 10 4 1 General Technical Data 10 4 2 24 V Input 10 4 3 Output 11 5 Connector Assignments 12 5 1 24 V Input Voltage P1 12 5 2 CompactPCI Connector Strip J2 13 6 Cabling of the CompactPCI Backpla...

Page 6: ...om 18 V to 32 V and can deliver up to 50 W of power for each voltage source consumption of 120 W The 24 V input voltage is fed via a PHOENIX CONTACT MINI COMBICON connector in the front panel The CPCI...

Page 7: ...void this please discharge the static electricity from your body by touching the metal case of the CPCI system before you touch the CPCI PS24 The input of the unit is not internally fused An external...

Page 8: ...16 Hardware Manual Doc No I 2301 21 Rev 1 0 CPCI PS24 J2 CPCI backplane Circuit to the CPCI backplane 15 pin multipoint connector DIN 41612 construction H Mini Combicon connector CPCI PS24 24 V DC Fro...

Page 9: ...LED Colour Function Indicator State Description LED name in schematic diagram 3 3 V Green Output voltage on 3 3 V Output voltage on LED130 5 V Green Output voltage on 5 V Output voltage on LED131 24...

Page 10: ...rom functional earth FE and output Electrical grounding The input shield line should be externally connected to FE to meet the EMC requirements The input shield line is connected to the front panel of...

Page 11: ...ons The outputs are SELV safety extra low voltage acc EN 60950 1 The outputs are electrically isolated from FE and input The outputs should be externally connected to FE It is a good practice to conne...

Page 12: ...ON CONNECTOR MC 1 5 3 G 3 81 Line connector PHOENIX CONTACT MC 1 5 3 ST 3 81 Order number 1803581 Pin Position Pin Assignment Pin Signal 1 GND 2 Shield 3 24 V Signal Description GND ground Shield shie...

Page 13: ...3 V 3 3 V 10 12 GND 5 V GND 5 V 14 16 5 V 5 V 18 20 n c n c 22 24 n c GND Sense 3 3 V 26 28 Sense 3 3 V GND Sense 5 V 30 32 Sense 5 V Signal Description n c not connected GND reference potential of t...

Page 14: ...f the CompactPCI Backplane 6 Cabling of the CompactPCI Backplane Table 5 Cables of the 15 pin female multipoint connector to the CPCI backplane Page 14 of 16 Hardware Manual Doc No I 2301 21 Rev 1 0 C...

Page 15: ...Declaration of Conformity 7 Declaration of Conformity CPCI PS24 Hardware Manual Doc No I 2301 21 Rev 1 0 Page 15 of 16...

Page 16: ...glish manuals see table below Please download the manuals as PDF documents from our esd website www esd eu for free Manuals Order No CPCI PS24 ME Hardware manual in English I 2301 21 Table 7 Available...

Reviews: