Connector Assignments
5.3 IRIG-B, Trigger and I/Os (CAN-USB/400-IRIG-B only)
INFORMATION
The IRIG-B, Trigger and I/O-option is only available on CAN-USB/400-IRIG-B
(C.2069.06).
Device connector:
15-pin DSUB connector, female
Pin Position:
Pin Assignment:
Signal
Pin
Signal
TRIG0
1
9
TRIG1
TRIG2
2
10
TRIG3
TRIG4
3
11
TRIG5
SYNC1-
4
12
SYNC1+
SYNC2-
5
13
SYNC2+
GND
6
14 IRIG-B_RX+
IRIG-B_RX-
7
15
IRIG-B_A+
IRIG-B_A-
8
Signal Description:
TRIG0...TRIG5 ...
miscellaneous I/Os, 3.3 LVTTL level,
e.g. usable as trigger inputs for CAN Error Injection
SYNC1+/-, SYNC2+/- ...
RS-485 interface for timestamp synchronisation of
CAN-USB/400-IRIG-B modules
GND ...
signal reference GND
IRIG-B_RX+/- ...
digital IRIG-B input acc. to standard 200-87, format B003
IRIG-B_A+/- ...
analog IRIG-B input acc. to standard 200-87, format B122
connector housing ...
connector housings of IRIG-B, CAN0, CAN1 and USB are
connected to each other and via 10 nF to both CAN_GNDs of
CAN0 and CAN1
NOTICE
To ensure the EC Conformity for the wiring of the IRIG-B interface at the 15-pin DSUB
connector a shielded twisted pair cable must be used.
In an adapter cable FE (functional earth) shall be connected to the cable shield.
The shield is intended to be connected to functional earth, via the host system or via the
remote station or via a separate connection of the shield. See figure 6.
Page 20 of 34
Hardware Manual • Doc. No.: C.2069.21 / Rev. 1.4
CAN-USB/400 / -IRIG-B / -FD
1
2
3
4
5
9
10
11
12
6
7
8
13
14
15