TB-5508
October 2016 Page 1 of 2
SPI Counter Workstation Ionizer
Operation, Installation and Maintenance
Figure 1. SPI Counter Workstation Ionizer
Description
The SPI Counter Workstation Ionizer is designed to
effectively eliminate localized static charges which exist
in the work area.
Item
Description
Counter Workstation Ionizer, 120VAC
Counter Workstation Ionizer, 220VAC
Replacement Emitters, Pack of 2
NOTE: If your ionizer was manufactured prior to 2009,
as your replacement emitter pins.
Contact customer service should you need assistance
with determining your ionizer’s year of manufacture.
Operation
The Counter Workstation Ionizer comes completely
balanced and ready to use.
1. Place the ionizer on a flat, level surface.
2. Plug the ionizer into an appropriate electrical outlet.
3. Power the ionizer using the power switch located
at the back.
FOR BEST RESULTS
1. Keep the targeted area clear and free from
obstructions of ion flow.
2. Effective ionization range: 12" (305 mm)
3. Position the ionizer so its emitter points are
directed towards the area to be ionized.
REMEMBER
1. Keep the work area clear of all static generative
materials.
2. Use only approved static control grounding
methods and material handling equipment.
3. By properly using ionized air, all static potentials
in the work area are greatly reduced, even when
humidity levels decrease.
CAUTION:
Care should be exercised during handling
to prevent the unit from falling face down. The delicate
emitter pins will be damaged or broken if this happens.
Maintenance
The Counter Workstation Ionizer is designed to be
virtually maintenance free. The emitter points can be
cleaned when there is a visible accumulation of dirt.
Generally this would be twice a year, depending on the
cleanliness level of the working environment.
1. Check the emitter points for dirt accumulation.
2. Be sure the unit is unplugged.
3. Wipe emitter point with a swab dampened in
isopropyl alcohol.
4. The outside case may be wiped down with a soft
damp cloth.
Calibration
The Counter Workstation Ionizer is factory set to
achieve a maximum balanced ion output in standard,
non-air assisted applications. To certify calibration,
we recommend ANSI/ESD association standard ANSI/
ESD STM3.1.
Objective: To observe, test and record performance
levels of ionization units, utilizing readily available
equipment, thereby verifying or certifying calibration.
EQUIPMENT USED
Charged Plate Analyzer
PROCEDURE
1. Position the Counter Workstation Ionizer 12 inches
(305 mm) away from the face of the Charged Plate
Analyzer.
TECHNICAL BULLETIN TB-5508
Made in the
United States of America