Calibration Procedure – 

DIGITAL WALL MOUNTED TIRE INFLATOR 

Model #10964 

 

NOTE: 

Make sure the inflation unit is 

disconnected

 from the power supply before 

starting Step 1. 

 

Step 1: 

Connect the inflator 

Inlet

 to a >100 PSI air source. 

 

 

Step 2: 

 

Press and hold the Target pressure control buttons (“

+

” and “

“) on the faceplate of the 

10964 Inflator.  

 

 

 

Step 3: 

 

Turn on the inflator and when the LCD display shows “

06A

” code release control 

buttons (“

+

” and “

–“) 

 

 

 

Step 4: 

 

Press the “

i/SET

” unit option button until the “

CAL

” code is shown on the inflator’s LCD 

display.  

 

 