11
EN
HOW TO CHECK
THE BAROMETRIC PRESSURE
The current and historical barometric pressure is shown on
the atmospheric pressure window.
To monitor local barometric pressure, select "0" meters as the
altitude setting. To monitor Sea Level barometric pressure for a
certain altitude, select the local altitude. To set the altitude,
press and hold [ HISTORY ] button to enter the altitude
compensation setting mode. Use the [ ] or [ ] button to
select from -100 to 2500 meters. Press [ HISTORY ] button to
confirm and exit.
The atmospheric pressure can be displayed in mb/hPa or
inHg. The pressure unit is selected on the atmospheric
pressure slide switch.
If you want to check the pressure history for a particular
hour during the past 24 hours, press the [ HISTORY ]
button. Each press on the button will go back by an hour.
Holding down the button will increase the value rapidly.
LOW BATTERY INDICATION
When it is time to replace batteries, the respective low
battery indicator [
] will show up when the corresponding
channel is selected. The battery level of the main unit is
shown on the Weather Forecast Window when it is running
low.
HOW TO WALL MOUNT OR USE THE
TABLE STAND (REMOTE UNIT)
As for the remote unit, it has a wall-mount hole and a removable
stand. Use either to hold the unit in place.
Wall-Mount:
Table-Stand:
HOW TO WALL MOUNT OR USE THE
TABLE STAND (MAIN UNIT)
The unit can be wall-mounted using its recessed screw
holes or placed on a flat surface using the detachable table
stand.
T h e r m o -
H y g r o S e n
s o r