Warrior 500i CC/CV
Mains voltage
380 V 3~ 50/60 Hz
400 V 3~ 50/60 Hz
415 V 3~ 50/60 Hz
Mains cable area
4 × 6 mm²
4 × 6 mm²
4 × 6 mm²
Maximal current
rating I
max
38 A
36 A
35 A
I
1eff
MIG/MAG
TIG
MMA
28 A
23 A
29 A
27 A
22 A
28 A
26 A
26 A
26 A
Fuse
anti-surge
type C MCB
35 A
32 A
35 A
32 A
35 A
32 A
Table 2. Recommended fuse sizes and minimum cable area Warrior 500i CC/CV
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with
Swedish regulations. Use the power source in accordance with the relevant
national regulations.
Connection instruction
The power source is factory set to 400 V AC. If another mains voltage setting is required, the
cable on the printed circuit board has to be moved and put in the correct position. Also the
label, at the rear of the power source, marked with the mains voltage setting must be
updated. This operation must be done by a person who has the appropriate electrical
knowledge.
NOTE!
This power source version is designed for a nominal input voltage from 380 to
415 V AC. ESAB does not recommend a connection of the cable on the circuit
board in the position of 440 , 460 or 575 V AC.