![ESAB TAF 1251 Instruction Manual Download Page 8](http://html.mh-extra.com/html/esab/taf-1251/taf-1251_instruction-manual_2425173008.webp)
3 TECHNICAL DATA
0449 510 101
- 8 -
© ESAB AB 2018
3
TECHNICAL DATA
TAF 1251
Voltage
346/400/415/500 V, 1 ̴ 50 Hz
400/440/550 V, 1 ̴ 60 Hz
Primary current
I
max
249 A
Permissible load at:
100 % duty cycle
1250 A / 44 V
Setting range
400 A / 28 V – 1250 A / 44 V
No-load voltage
73 V
No-load power
240 W
Efficiency
87%
Power factor
0.77
Apparent power
86.2 kVA
Active power
64.9 kW
Weight
608 kg
Dimensions L × W × H
774 × 598 × 1228
Insulation class (transformer):
F
Enclosure class
IP 23
Enclosure class
The
IP
code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked
IP23
is intended for indoor and outdoor use.