26
sectIon 3
InstallatIon
3.7 Interface cables
CNC Interface (24 Pin)
3.6.2 Marking with two parallel epp-600’s
Water Cooler Interface (8 Pin)
Two EPP-600’s, connected in parallel, and can be used for marking down to 24A and cutting from 100A up to 1000A. Two
simple modifications can be made to the Supplemental Power Source in order to permit marking down to 12A. The modi-
fications are necessary only if marking down to 12A is required.
fIelD changes to perMIt MarKIng DoWn to 12a:
1. CHANGES TO THE PRIMARY POWER SOURCE: None
2. CHANGES TO THE SUPPLEMENTAL POWER SOURCE:
A. Unplug the WHT wire from the coil of K12
B. Remove the ORN jumper from TB7-11 and connect both ends of the jumper on TB7-12.
operatIon of tWo parallel epp-600’s:
1. Provide Contactor On/Off, Cut/Mark, & Pilot Arc Hi/Lo signals to both Primary & Supplemental units for both cutting &
marking. When marking, both power sources are powered up, but the Mark Signal disables the output of the Supple-
mental Power Source if it has been modified for marking down to 12A. If the Supplemental Power Source has not been
modified, it will provide the same output current as the Primary Power Source
2. Feed the same V
REF
signal into both the Primary & Supplemental units for both cutting & marking. For installations
with a modified Secondary Power Source, the output current transfer function for marking is that of the Primary Power
Source: I
OUT
= 80 x V
REF
. For cutting, it is the sum of the Primary & Supplemental Power Sources: I
OUT
= 160 x V
REF
. For
installations with an unmodified Secondary Power Source, the output current transfer function for both cutting and
marking is I
OUT
= 160 x V
REF
.
Summary of Contents for Precision Plasmarc EPP-600
Page 1: ...EPP 600 Plasma Power Source Instruction Manual 0558006514 08 2010 ...
Page 4: ...4 ...
Page 42: ...42 section 4 operation ...
Page 63: ...63 section 6 TROUBLESHOOTING 80 ...
Page 70: ...70 section 7 replacement parts ...
Page 71: ...71 section 7 replacement parts ...
Page 72: ...72 section 7 replacement parts ...
Page 73: ...73 section 7 replacement parts ...
Page 74: ...74 section 7 replacement parts ...
Page 75: ...75 section 7 replacement parts EPP 400 Only 2 Places EPP 600 Only 2 Places ...
Page 76: ...76 section 7 replacement parts ...
Page 77: ...77 section 7 replacement parts 49 ...
Page 78: ...78 section 7 replacement parts ...
Page 79: ...79 section 7 replacement parts ...
Page 80: ...80 section 7 replacement parts ...
Page 81: ...81 section 7 replacement parts 35751Y 35752Y 0558006169 ...
Page 83: ...83 section 7 replacement parts ...
Page 84: ...84 section 7 replacement parts ...
Page 85: ...85 section 7 replacement parts ...
Page 86: ...86 section 7 replacement parts 0558954035 ...
Page 87: ...87 section 7 replacement parts 4600610 3 62 W ...
Page 88: ...88 notes ...