165
SECTION 5
TROUBLESHOOTING
Refer to system schematic. Replace the transformer module if the
correct secondary voltages are not present.
3.
If everything above checks out all right, then the PCB1 Control Board
should be replaced.
D. Fault light activates when torch switch is closed.
The machine monitor conditions necessary for the safe operation of the
Powercut-1500. The fault lights will glow under the following conditions
and operations will come to a stop.
1.
High/Low line voltage
. The "AC LINE" light will
blink to indicate that
the input voltage is outside the +/- 15% range of the nominal voltage.
2.
Gas Flow indicator
- The fault light will blink to indicate that the air
flow is low or that the torch is not providing any back pressure.
a.
Check the air pressure at the machine regulator. It should be
adjusted to 80 psig. If no air pressure, check the air at the supply
point. Also, check for any obstructions in the air hose.
b.
Air flow may be blocked at the torch tip. Check the torch
consumables (see Figure 3.3). Also check for any obstructions in
the torch leads.
NOTE: If above items check OK , the problem is internal. Send unit
to an Authorized Repair Station for repair.
c.
Put the ‘Air Check’ switch to On position. Air should flow through
torch. If not, and air pressure is set at required 80 PSIG, check
gas Solenoid (SOL1) for proper operation.
d.
Air Check switch may also be malfunctioning if the air is flowing
continuously or putting in the On position does not turn air on.
3.
Over Temperature indicator .
The fault light will blink to indicate that
the machine is overheated. This generally indicates that the air flow
has been blocked. Clear blockage and allow the power source to cool
before operating.
a.
Thermal Switch (TS1) may be open. It will open if the heat sink
temperature reaches 80°C. With the machine power off, check
the continuity between P6-7 and P6-8 of the control board. If
the switch is OK, then the ohmmeter should read a direct
short. If not then it should read open.
b.
If the switch is malfunctioning, replace it. Clean the surface of the
heat sink before installing the switch.
4.
Fault Indicator
. When this light blinks, either the system failed to
initiate a pilot arc after a number of attempts, or there has been an
over-current event within the system.
a.
If the light blinks for 10 seconds and then stops, then the problem
is pilot arc initiation. Check the consumables in the torch.
b.
If the light continues to blink, and the system does not reset, then
the fault is an over-current event. One likely source of an over-
current fault is a nozzle to electrode short. Turn off the machine
and inspect the torch and its consumables. Replace the
consumables as needed. Turn the machine back on. If the problem
occurs again, the machine may require service.
Summary of Contents for POWERCUT-1500
Page 2: ...POWERCUT 1500 0558003745 012003 ...
Page 3: ......
Page 4: ......
Page 6: ...ii ...
Page 7: ...POWERCUT 1500 0558003745 102002 Instruktionsbok SE ...
Page 12: ...4 ...
Page 16: ...8 ...
Page 20: ...12 ...
Page 28: ...20 ...
Page 29: ...POWERCUT 1500 0558003745 012003 Bedienungsanleitungen DE ...
Page 34: ...24 INHALTSVERZEICHNIS ...
Page 38: ...28 TEIL 1 BESCHREIBUNG ...
Page 42: ...32 TEIL 2 INSTALLIERUNG ...
Page 50: ...40 TEIL 3 BETRIEB ...
Page 51: ...POWERCUT 1500 0558003745 102002 Manuel d Instruction FR ...
Page 56: ...44 ...
Page 60: ...48 ...
Page 64: ...52 ...
Page 72: ...60 ...
Page 73: ...POWERCUT 1500 0558003745 102002 Manual de instrucciones ES ...
Page 78: ...64 ...
Page 82: ...68 ...
Page 86: ...72 ...
Page 94: ...80 ...
Page 95: ...POWERCUT 1500 0558003745 102002 Instruction Manual GB ...
Page 100: ...84 ...
Page 104: ...88 ...
Page 108: ...92 ...
Page 116: ...100 ...
Page 117: ...POWERCUT 1500 0558003745 102002 Instruktionsbog DK ...
Page 122: ...104 ...
Page 126: ...108 ...
Page 130: ...112 ...
Page 138: ...120 ...
Page 139: ...POWERCUT 1500 058003745 102002 Brukerhåndbok NO ...
Page 144: ...124 ...
Page 148: ...128 ...
Page 152: ...132 ...
Page 160: ...140 ...
Page 161: ...POWERCUT 1500 0558003745 102002 Käyttöohjeet FI ...
Page 166: ...144 ...
Page 170: ...148 ...
Page 174: ...152 ...
Page 182: ...160 ...
Page 193: ...171 Powercut 1500 Schematic Diagram 0558003513 ...
Page 194: ...172 ...
Page 201: ...179 Instruction Manual Changes ORIGINAL RELEASE ...