43
section 6
troubleshootinG
problem
possible cause
action
Very high Output current ac
-
companied by either a left or
right over current (LED 6)
Shorted IGBT
Replace the IGBTs
Current pot set too high
Lower the current setting
Faulty left PWM / Drive PCB
Replace left PWM / Drive PCB
High remote current signal
Decrease remote current signal
Faulty PCB1
Replace PCB1 P/N 0558038312
LED 10 - (red) Left IGBT Un
-
saturated
Black wire connecting IGBT (Q2) collector to P3 of the
left PWM / Drive PCB (PCB2) is disconnected.
Secure connector
Shorted Freewheeling Diode(s)
Replace freewheeling diode(s)
Loose or unplugged P1 connector at the left PWM /
Drive PCB
Secure P1
Loose or unplugged P10 connector at PCB1
Secure P10
Faulty PCB1
Replace PCB1 P/N 0558038312
Faulty left PWM / Drive PCB
Replace PCB2 P/N 0558038324
LED 11 - (red) Right IGBT
Unsaturated
Black wire connecting IGBT (Q5) collector to P3 of the
right PWM / Drive PCB (PCB3) is disconnected.
Secure connector
Shorted Freewheeling Diode(s)
Replace freewheeling diode(s)
Loose or unplugged P1 connector at the left PWM /
Drive PCB
Secure P1
Loose or unplugged P10 connector at PCB1
Secure P11
Faulty PCB1
Replace PCB1 P/N 0558038312
Faulty right PWM / Drive PCB
Replace PCB3 P/N 0558038324