SECTION 5
TROUBLESHOOTING
20
C.
Air does not shut off
Is air check switch OFF?
Yes
No
Turn switch OFF
Does arc start when nozzle contacts work without depressing torch switch?
Yes
No
Check for short in torch switch
Does air flow even when PCM-750i power switch is OFF?
Yes
No
Replace
Repair power
solenoid valve
source
Summary of Contents for PCM-750i
Page 25: ...25 Figure 5 1 PCM 750i Series A Schematic Diagram 460 V 3 Phase Input D 35511 A ...
Page 26: ...26 Figure 5 2 PCM 750i Series A Wiring Diagram 460 V 3 Phase Input D 35510 A ...
Page 27: ...27 Figure 5 3 PCM 750i Series A Schematic Diagram 230 V 1 Phase Input D 35507 A ...
Page 28: ...28 Figure 5 4 PCM 750i Series A Wiring Diagram 230 V 1 Phase Input D 35506 A ...