ESAB Origo Tig 4300iw AC/DC Instruction Manual Download Page 12

5 OPERATION

0460 157 301

- 12 -

© ESAB AB 2018

5

OPERATION

General safety regulations for handling the equipment can be found in the "SAFETY"
chapter of this manual. Read it through before you start using the equipment!

5.1

Connections and control devices

1

Connection for cooling water from the
torch - RED

9

Main power supply switch, 0 / 1 / START

2

Connection with ELP* for cooling water to
the torch - BLUE

10

White indicating lamp - Power supply ON

3

Cooling water filler

11

Orange indicating lamp - Overheating

4

Connection for return cable (+)

12

Control panel (see the respective
instructions)

5

Connection for remote control

13

Connection for cooling water. Not used on
this model.

6

Connection for welding cable (-)

14

Connection for cooling water. Not used on
this model.

7

Connection for start signal from the
welding torch

15

Connection for gas hose

8

Connection for gas to the TIG torch

16

Fuse 42 V (from serial number
950-xxx-xxx only)

*ELP = ESAB Logic Pump, see "Cooling unit" section.

Summary of Contents for Origo Tig 4300iw AC/DC

Page 1: ...Origo Instruction manual 0460 157 301 GB 20181217 Valid for 950 xxx xxxx Tig 4300iw AC DC...

Page 2: ......

Page 3: ...ource 10 4 3 Mains power supply 11 5 OPERATION 12 5 1 Connections and control devices 12 5 2 Key to symbols 13 5 3 Turning on the power source 13 5 4 Fan control 13 5 5 Overheating protection 13 5 6 C...

Page 4: ...y precautions must meet the requirements that apply to this type of equipment The following recommendations should be observed in addition to the standard regulations that apply to the workplace All w...

Page 5: ...ELECTRIC AND MAGNETIC FIELDS Can be dangerous to health Welders having pacemakers should consult their physician before welding EMF may interfere with some pacemakers Exposure to EMF may have other he...

Page 6: ...uipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic...

Page 7: ...for the product can be found in the ACCESSORIES chapter of this manual 2 1 Equipment The power source is delivered with 5 m 16 4 ft mains cable including the plug 5 m 16 4 ft return cable instruction...

Page 8: ...A 22 6 V Permissible load at MMA 40 duty cycle 430 A 37 2 V 60 duty cycle 400 A 36 0 V 100 duty cycle 315 A 32 6 V Power factor at maximum current TIG 0 89 MMA 0 89 Efficiency at maximum current TIG 7...

Page 9: ...ed coolant Liquid quantity 5 5 l 1 45 gal Maximum water flow 2 0 l min 0 53 gpm Duty cycle The duty cycle refers to the time as a percentage of a ten minute period that you can weld or cut at a certai...

Page 10: ...em It is the responsibility of the installer or user of the equipment to ensure by consultation with the distribution network operator if necessary that the equipment is connected only to a supply wit...

Page 11: ...ing plate with supply connection data Recommended fuse sizes and minimum cable areas Tig 4300iw AC DC TIG MMA Mains voltage 400 V 3 50 Hz 400 V 3 50 Hz Mains cable area mm2 4G4 4G4 Phase current I1eff...

Page 12: ...e torch BLUE 10 White indicating lamp Power supply ON 3 Cooling water filler 11 Orange indicating lamp Overheating 4 Connection for return cable 12 Control panel see the respective instructions 5 Conn...

Page 13: ...ed so that it is available next time the unit is started 5 4 Fan control The power source fans continue to run for 6 5 minutes after welding has stopped and the unit switches to energy saving mode The...

Page 14: ...de Function when welding To start welding the welder presses the torch trigger switch The power source energises the torch and starts wire feed and the cooling water pump To stop welding the welder re...

Page 15: ...ng the warranty period 6 1 Cleaning the filter Remove the front grille with the filter 1 Swing out the front grille 2 Remove the filter 3 Blow the filter clean with compressed air reduced pressure Rep...

Page 16: ...ring welding Check whether the thermal cut outs have tripped indicated by the orange lamp on the front panel and a fault code is shown in the panel Check the coolant flow Check the main power supply f...

Page 17: ...nd European standards IEC EN 60974 1 2 3 and IEC EN 60974 10 It is the obligation of the service unit which has carried out the service or repair work to make sure that the product still conforms to t...

Page 18: ...DIAGRAM 0460 157 301 18 ESAB AB 2018 DIAGRAM...

Page 19: ...DIAGRAM 0460 157 301 19 ESAB AB 2018...

Page 20: ...DIAGRAM 0460 157 301 20 ESAB AB 2018...

Page 21: ...DIAGRAM 0460 157 301 21 ESAB AB 2018 Cooling Unit...

Page 22: ...ng power source Origo Tig 4300iw AC DC TA24 AC DC 0459 839 008 Spare parts list Tig 4300iw AC DC 0459 839 003 Spare parts list Control Panel Origo TA24 AC DC 0459 944 xxx Instruction manual Control Pa...

Page 23: ...SPARE PARTS LIST 0460 157 301 23 ESAB AB 2018 SPARE PARTS LIST Item Ordering no Denomination 1 0458 398 001 Filter 2 0458 383 991 Front grille...

Page 24: ...te control unit AT1 CF CAN MMA and TIG rough and fine setting of current 0460 315 880 T1 Foot CAN Foot control unit Including 5 m 16 4 ft cable 0459 554 880 0459 554 881 0459 554 882 0459 554 883 0459...

Page 25: ...bly incl 8 m 26 2 ft cable assembly 0700 300 637 0700 300 639 TXH 401Wr HD incl 4 m 13 1 ft cable assembly incl 8 m 26 2 ft cable assembly 0459 491 912 Remote adapter kit for TXH 401wr 401wr HD incl h...

Page 26: ...For contact information visit esab com ESAB AB Lindholmsall n 9 Box 8004 402 77 Gothenburg Sweden Phone 46 0 31 50 90 00 http manuals esab com...

Reviews: