WARNING!
During transport, the rear wheels of the power source are in their forward
position. Before use, place the wheels in their rear position.
4.3
Electrical installation
4.4
Mains power supply
Check that the unit is connected to the correct mains power supply voltage, and that it is
protected by the correct fuse size. A protective earth connection must be made, in
accordance with regulations.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable areas
Mig C420 PRO
3~ 50 Hz
Voltage V
400 - 415
Current A
at 100% duty cycle
19
at 60% duty cycle
27
at 50% duty cycle
30
Cable area mm
2
4 x 4
Fuse, slow A
25