-- 6 --
mxx02cwe
Enclosure class
IP 23
Application classification
Origo
TM
Mig 5002cw
Mains voltage
230/400--415/500 V 3
∼
50 Hz
230/440--460 V 3
∼
60 Hz
Permissible load at
60 % duty cycle
100% duty cycle
Mig/Mag: 500 A / 39 V; MMA: 500 A / 40 V
Mig/Mag: 400 A / 34 V; MMA: 400 A / 36 V
Setting range (DC)
MIG/MAG
MMA
Mig/Mag: 16A / 8V--500 A / 39 V
MMA: 16A / 8V--500 A / 40 V
Open circuit voltage
Mig/Mag: 62V; MMA: 68V
Open circuit power
with cooling unit
in energy saving mode
(15 min after last welding)
550 W
750 W
60W
Power factor
at maximum current
0,90
Efficiency
at maximum current
72 %
Control voltage
42 V, 50/60 Hz
Dimensions lxwxh
830 x 640 x 835 mm
Weight
with cooling unit
185 kg
199 kg
Operating temperature
--10 to +40
˚
C
Enclosure class
IP 23
Application classification
Origo
TM
Mig 6502cw
Mains voltage
230/400--415/500 V 3
∼
50 Hz
230/440--460 V 3
∼
60 Hz
Permissible load at
60 % duty cycle
100% duty cycle
Mig/Mag: 650 A / 44 V; MMA: 650 A / 44 V
Mig/Mag: 500 A / 39 V; MMA: 500 A / 40 V
Setting range (DC)
MIG/MAG
MMA
Mig/Mag: 16A / 8V--650 A / 44 V
MMA: 16A / 8V--650 A / 44 V
Open circuit voltage
Mig/Mag: 62V; MMA: 68V
Open circuit power
with cooling unit
in energy saving mode
(15 min after last welding)
670 W
870 W
60W
Power factor
at maximum current
0,90
Efficiency
at maximum current
76 %
Control voltage
42 V, 50/60 Hz
Dimensions lxwxh
830 x 640 x 835 mm
Weight
with cooling unit
222 kg
236 kg
Operating temperature
--10 to +40
˚
C
GB
Summary of Contents for Origo Mig 4002c
Page 13: ... 13 document ...
Page 14: ...Diagram 14 dmxx02cw Mig 4002cw 5002cw 6502cw 400 415 V ...
Page 15: ... 15 dmxx02cw Mig 4002cw 5002cw 6502cw 400 415 V ...
Page 16: ... 16 dmxx02cw Mig 4002c 5002c 6502c 400 415 V ...
Page 17: ... 17 dmxx02cw Mig 4002c 5002c 6502c 400 415 V ...
Page 18: ... 18 dmxx02cw Mig 4002cw 5002cw 6502cw 230 550 V ...
Page 19: ... 19 dmxx02cw Mig 4002cw 5002cw 6502cw 230 550 V ...
Page 20: ... 20 dmxx02cw Mig 4002c 5002c 6502c 230 550 V ...
Page 21: ... 21 dmxx02cw Mig 4002c 5002c 6502c 230 550 V ...