ESAB Origo Mig 320 Instruction Manual Download Page 4

-- 4 --

320e

WARNING!

Read and understand the instruction manual

before installing or operating.

WARNING

READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.

ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAU-

TIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE

BASED ON MANUFACTURERS’ HAZARD DATA.

ELECTRIC SHOCK -- Can kill

S

Install and earth the welding unit in accordance with applicable standards.

S

Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.

S

Insulate yourself from earth and the workpiece.

S

Ensure your working stance is safe.

FUMES AND GASES -- Can be dangerous to health

S

Keep your head out of the fumes.

S

Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone

and the general area.

ARC RAYS -- Can injure eyes and burn skin.

S

Protect your eyes and body. Use the correct welding screen and filter lens and wear protective

clothing.

S

Protect bystanders with suitable screens or curtains.

FIRE HAZARD

S

Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.

NOISE -- Excessive noise can damage hearing

S

Protect your ears. Use earmuffs or other hearing protection.

S

Warn bystanders of the risk.

MALFUNCTION -- Call for expert assistance in the event of malfunction.

PROTECT YOURSELF AND OTHERS!

Do not use the power source for thawing frozen pipes.

WARNING!

This product is solely intended for arc welding.

Do not dispose of electrical equipment together with normal waste!

In observance of European Directive 2002/96/EC on Waste Electrical and Electronic

Equipment and its implementation in accordance with national law, electrical equipment

that has reached the end of its life must be collected separately and returned to an

environmentally compatible recycling facility. As the owner of the equipment, you should

get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human health!

GB

Summary of Contents for Origo Mig 320

Page 1: ...Valid for serial no 626 0349 301 110 061025 Mig 320 Origo Instruction manual...

Page 2: ...ly of components 6 5 3 Assembly of stabilizer 7 5 4 Electrical installation 7 5 5 Mains power supply 8 6 OPERATION 9 6 1 Connection and control devices 9 6 2 Overheating protection 9 6 3 Inductance co...

Page 3: ...ll acquainted with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1...

Page 4: ...ng screen and filter lens and wear protective clothing S Protect bystanders with suitable screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore that there are no inflamma...

Page 5: ...0 Hz 230 440 460 3 60Hz Permissible load at100 duty cycle 195 A 24 V 195 A 24 V at 60 duty cycle 250 A 27 V 250 A 27 V at 30 duty cycle 320 A 30 V 320 A 30 V Setting range DC 40A 16V 320A 30V 40A 16V...

Page 6: ...or industrial use In a domestic environment this product may cause radio interference It is the user s responsibility to take adequate precautions 5 1 Placing Position the welding power source such wa...

Page 7: ...ilizer if counter balance is to be installed on machine The stabilizer is an accessory Ordering number you can find on page 15 Attention Utilization of counter balance without stabilizer may cause the...

Page 8: ...50 60 Hz 3 50 Hz 3 60 Hz 3 60 Hz Voltage V 230 400 415 500 230 440 460 Current A at100 duty cycle 16 9 7 16 8 at 60 duty cycle 23 14 10 23 12 at 30 duty cycle 35 20 16 34 18 Cable area mm2 2 2 2 4 x...

Page 9: ...induc tance 2 Switch precise control 8 Connection for return cable low induc tance 3 Switch coarse control 9 Connection for welding current cable 4 Indicating lamp power supply ON 10 Connection for co...

Page 10: ...cted S Check that correct current value is set S Check to see whether the MCB has tripped Welding current is interrupted during welding S Check whether the thermal overload trip has operated indicated...

Page 11: ...Diagram 11 dM320 OrigoTM Mig 320 400V...

Page 12: ...12 dM320 OrigoTM Mig 320 230 500V...

Page 13: ...13 oM320 Valid for serial no 626 XXX XXXX Ordering numbers 0349 302 676 OrigoTM Mig 320 400 415V 3 50Hz 0349 303 562 OrigoTM Mig 320 400 415V 3 50Hz with meter 0349 302 613 OrigoTM Mig 320 230 400 415...

Page 14: ...cessories 14 aM320 NO TAG Feeder with capsulated bobbin OrigoTM Feed 302 OrigoTM Feed 304 0459 116 781 0459 116 882 Digital meter 0349 302 598 Transformer kit for CO2 heater 0349 302 250 Filter 0349 3...

Page 15: ...ion 061025 15 aM320 Connection sets Connection set 1 7m Connection set 10m Connection set 15m Connection set 25m Connection set 35m 0469 836 880 0469 836 881 0469 836 882 0469 836 883 0469 836 884 Sta...

Page 16: ...2 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Te...

Reviews: