Technical data:

 

This powered respirator is light-weight and easy to handle. It is equipped with a replaceable particulate 
filter. The system affords reliable protection against particulates and aerosols. 
Initial Air flow: 220 Litres/ min. Minimum flow rate 170 Litres/ min. 
Weight with filter: 880 grammes
Type of filter: PSL
Type of Battery: Replaceable and rechargeable Li-ion
Actual Protection Factor (APF) 20
Noise level: 62dBA
Operation greater than 8 hours in a clean environment

Certification  EN 12941:1998+A1:2003+A2:2008

Certified by

:   DEKRA-EXAM GmbH

Symbols

 :

Refer to the manufacturer’s instruction manual                             

Store between       0 - +55º C

Expiry date  year/month 

Maximum storage humidity          <75% 

Warranty:

The Origo™Air Blower unit is guaranteed for a period of 12 months from date of purchase against 
mechanical or electrical defects.
The Origo™Air battery is guaranteed for a period of 6 months from the date of purchase.

 

The Company undertakes to exchange or repair without charge, any part found to be defective within 
this period. Alternatively and at it’s discretion. the Company may replace. 
This guarantee is subject to:- 
The Origo™Air unit has been used solely for the purpose for which it is intended. 
The Origo™Air unit has not been subject to misuse, accident, modification or repair. 
N.B. In the event of a claim, contact the retailer from which the Origo™Air unit was purchased. 

This guarantee does not cover normal wear and tear This guarantee does not affect your legal rights.

ESAB Group (UK) Ltd.,

Hanover House, Queensgate,

Britannia Road, Waltham Cross,

Hertfordshire, EN8 7TF

England

www.esab.co.uk

-xxºC

+yyºC

yyyy/mm

XX

ESAB Origo-Air User Manual Enlis8   8

5/8/09   11:44:57

Summary of Contents for Origo Air

Page 1: ...PORATING A WELDING HELMET OR IMPACT PROTECTIVE FACESHIELD CLASS TH2P DEVICE USER INSTRUCTION MANUAL Important This manual must be read and fully understood before the Origo Air unit is used This manua...

Page 2: ...st be used strictly in accordance with this instruction lea et and the instructions supplied with corresponding head units When the blower unit is switched off little or no respiratory protection is t...

Page 3: ...nge the battery for a fully charged one Only when the unit will function with the alarm switched off and the ow rate has been tested to be acceptable should the user return to the work place The linea...

Page 4: ...ion See Picture 4 It will now be possible to pull the lter away from the Unit Fitting the Filters First Check the lter for any signs of damage In particular check for any signs of damage to the foam s...

Page 5: ...Donning the Blower Unit Place belt around waist and fasten snap t buckle To adjust t of belt pull free end away from the Velcro fastening and pull through buckle The belt should be tightened loosened...

Page 6: ...any solvents or abrasive cleaning agents be used The unit must not be dried using hot air or radiant heat The unit should continue to provide protection to the designed speci cation for 2 to 3 years...

Page 7: ...the Battery Once the unit has reached it s MMDF it is best to leave it to run down completely before recharging The battery can either be charged whist installed in the blower unit or removed and char...

Page 8: ...period of 12 months from date of purchase against mechanical or electrical defects The Origo Air battery is guaranteed for a period of 6 months from the date of purchase The Company undertakes to exch...

Reviews: