M
38.9
When the PHG1A is not used, it is necessary to disconnect
the multipole connector
ATTENTION
The remote control PHG1A, which regulates the welding
current in the CC (STICK welding) mode and the welding
voltage in the CV (MIG/MAG welding) mode, is connected to
the front panel by means of a multipole connector.
When the remote control is connected to the remote control
connector (8), it is functional and automatically excludes the
front panel regulation.
The remote control can also be connected to the connector on
the wire feeder front panel but in this case it is necessary to
switch the wire feeder commutator so it can operate.
The polarity inverter (64A), if installed, can be operated from
the remote control.
Adjust the welding current control knob to the correct current
for the diameter and type of electrode being welded.
PUSH AND
SCREW TIGHT
02/11/04 79405-GB
REMOTE CONTROL PHG1A-PHG1A/PL
KHM
ONLY PL
VERSION
Summary of Contents for KHM 2x400 PS
Page 2: ......
Page 11: ...INSTALLATION KHM 2x400 PS M 2 7 KHM 2x400 PS KHM 2x400 PS...
Page 25: ...WARNING AND MAINTENANCE KHM 2x400 PS M 44 2...
Page 28: ......
Page 36: ...Spare parts KHM 2x400 PS ED 6...
Page 40: ...Spare parts KHM 2x400 PS ED 8...
Page 42: ...Spare parts KHM 2x400 PS ED 9...
Page 44: ...KIT DECAL 0794 999 859 KHM 2x400 PS 23 01 08 78410 GB V...
Page 47: ......