18
* Duty cycle is based on a 10-minute period; therefore, a 40% duty cycle means the machine may operate for 4 minutes with a cool
down period of 6 minutes; a 60% duty cycle means the machine may operate for 6 minutes with a cool down period of 4 minutes; a
100% duty cycle means the machine may operate continuously.
Table 2-2. HandyPlasma
®
550 Specifications
1.4 SPECIFICATIONS
Refer to Tables 2-2, 2-3, and Figures 2-1 and 2-2 for HandyPlasma
®
550 technical specifications.
SECTION 2
DESCRIPTION
Rated
Output
40% Duty Cycle*
35 A @ 120 V dc
60% Duty Cycle*
30 A @ 120 V dc
100% Duty Cycle*
22 A @ 120 V dc
Output Current Range
15 to 35 Amperes
Open Circuit Voltage
230 V dc Nominal
Rated Primary Input
@
35 A @ 120 VDC Output
230 VAC, 50/60 Hz,
1-Phase
27 A
Power Factor @
35 Amperes Output
81% (1-Phase)
Current Capacity
PT-31XL
50 A DCSP
Air Requirements
PT-31XL
250 cfh @ 80 psi
Dimensions of Handy
Plasma
®
550
Length
Height
Width
14.25-in. ( 362 mm)
12.7-in. (322 mm)
6.2-in. (156 mm)
Weight (less torch)
35 lbs (16 kg)