32
SECTION 5
TROUBLESHOOTING
B.
No Air
Is air hose connected?
Yes
No
Connect
Is air adjusted to 65 - 70 psig (4.5 - 4.8 bar)?
Yes
No
Adjust
Does air come on when main power turned on?
Yes
No
• No electrode in torch
• No valve pin in torch
•
Replace electrode
Check continuity of torch switch
• Replace valve pin
OK
No
Replace torch switch
Repair /replace power source
Summary of Contents for HandyPlasma 380