background image

8. PARTS LIST

8.1 EPR-X1

Drawing No.

Part No.

Description

700500900

EPR-X1 PAPR system  

1

700500901

EPR-X1 PAPR blower unit  

2

700500902

EPR-X1 PAPR pre-filter  

3

700500903

EPR-X1 PAPR P3 filter  

4

700500904

EPR-X1 PAPR battery  

5

700500905

EPR-X1 PAPR filter cover  

6

700500906

EPR-X1 PAPR spark arrestor  

7

700500907

EPR-X1 PAPR breathing tube  

8

700500908

EPR-X1 PAPR FR fabric tube cover  

9

700500909

EPR-X1 PAPR waist and shoulder harness  

10

700500910

EPR-X1 PAPR universal battery charger

11

700002413

EPR-X1 PAPR Air Flow Tester

1

2

3

4

5

6

7

8

9

10

11

Summary of Contents for EPR-X1

Page 1: ...tor User Instructions Please read these instructions carefully before using the equipment Incorrect use can result in danger to life and health Manual Number 0700500912 Revision Date 03 08 2022 Revisi...

Page 2: ...Can injure eyes and burn skin The arc like the sun emits ultraviolet UV and other radiation and can injure skin and eyes Hot metal can cause burns Training in the proper use of the processes and equi...

Page 3: ...all combustible materials well away from the work area or cover the materials with a protective non flammable covering Combustible materials include wood cloth sawdust liquid and gas fuels solvents p...

Page 4: ...ioning properly please do not Alter or modify in any way Touch any of the moving parts Allow water or other liquids to enter the impeller chamber the filter or battery com partment Make sure blower mo...

Page 5: ...rs 2 Only listed particulate filter and pre filter can be used together with this sys tem Filters from other manufacturers shouldn t be used under any circumstances and voids both the certification an...

Page 6: ...belt and the shoulder harness 2 EPR X1 blower assembly 3 Rechargeable lithium ion battery 4 Battery charger 5 The air flow tester 6 Main HEPA filter assembly includes pre filter and spark arrestor no...

Page 7: ...Clean the spark arrestor if necessary 6 Install a new filter by reversing the ac tions in steps 3 and 4 If the filter is wet or heavily loaded with particles or damaged it should be replaced Never at...

Page 8: ...y is fully charged it will maintain it at a 100 floating charge The charge time is 3 to 4 hours The battery will discharge itself after long storage periods Always charge the bat tery if the device wa...

Page 9: ...n 2 Unlock the hook and loop fastener and pass through the blower assem bly s belt loops 3 Pass the fastening belt through the gap on belt 4 Attach the hook and loop fastener onto the belt 5 Attach th...

Page 10: ...be to the Respira tory System and twist it clockwise to lock its position 1 Check that the respiratory tube is securely connected If the tube is broken replace it WARNING All components must be instal...

Page 11: ...he top of the tube 3 Press the ON button and maintain the tube in a vertical position at eye height 4 The air flow is sufficient if the marble reaches the minimum flow level O WARNING 1 The airflow mu...

Page 12: ...does not work please repair or change Respiratory System 6 3 Fitting 1 Adjust the tightness of the face seal and put on the head top 2 Adjust the headgear to suitable tight ness push and turn left to...

Page 13: ...tton and hold for 3 seconds the air flow will be at level 1 170L min Press the ON button once again the air flow will be at level 2 190L min Press the ON button once again the air flow will be at leve...

Page 14: ...PAPR P3 filter 4 700500904 EPR X1 PAPR battery 5 700500905 EPR X1 PAPR filter cover 6 700500906 EPR X1 PAPR spark arrestor 7 700500907 EPR X1 PAPR breathing tube 8 700500908 EPR X1 PAPR FR fabric tube...

Page 15: ...al surfaces Do not use water or other liquids Always replace the pre filter when the main filter is replaced 9 2 Storage The Respiratory System must be stored in a dry clean area in the temperature ra...

Page 16: ...nit OFF and allow it to cool No air flow no alarm 1 No power 2 Battery contact dam aged Charge the battery Check battery contact Battery run time is too short 1 Battery is not fully charged 2 Filter b...

Page 17: ...acity Filter status 12 MARKING EXPLANATION Powered filtering device EN 12941 1998 Respiratory protective devices Powered filtering devices incorporating a helmet or hood Requirements testing marking T...

Page 18: ...echanical or electrical defects The EPR X1 battery is guaranteed for a period of 6 months from the date of purchase The company undertakes to exchange or repair without charge if any part found to be...

Page 19: ...This page intentionally blank...

Page 20: ...ESAB Group Inc 2800 Airport Road Denton TX 76207 USA...

Reviews: