5.3

Mains power supply

Make sure that the welding power source is connected to the correct supply voltage

and that it is protected by the correct fuse rating. The standards for the country in

question must be complied with as regards the mains cable area. A protective earth

connection must be made in accordance with regulations.

5.3.1

Recommended fuse sizes and minimum cable areas

CaddyArc 150

Mains voltage

230 V

¦

10 %, 1--phase

Mains frequency

50--60 Hz

Fuse (delayed--action)

100A 20% duty cycle
120A 35% duty cycle
150A 35% duty cycle

10 A
16 A

20 A*)

Mains cable, area

3 x 2.5 mm

2

Welding cable, area

16 mm

2

*) Note! The installed plug is approved for max. 16A.

North American version:

The mains cable is approved for maximun 18 A.

Note!

The cable area and fuse rating above comply with Swedish regulations. Use

the welding power source in accordance with the relevant national regulations.

6

OPERATION

6.1

Connections and control devices

1

Main power supply switch, 0 / 1

4

Connection for remote control

2

Mains cable

5

Welding cable connector (+)

3

Connection for return cable (--)

6

Control panel (see 6.2)

3

and

5

are used for welding current supply and return cable connection during MMA

welding

GB

Summary of Contents for CaddyArc 150

Page 1: ...GB Valid for serial no 316 xxx xxxx 328 xxx xxxx 341 xxx xxxx 0459 263 001 GB 041101 CaddyArc 150 Instruction manual...

Page 2: ...te 5 5 3 Mains power supply 6 6 OPERATION 6 6 1 Connections and control devices 6 6 2 Control panel 7 6 3 Settings 8 6 4 Overheating protection 8 6 5 MMA welding 8 6 6 TIG welding 9 6 7 Remote control...

Page 3: ...e carried out by trained personnel well acquainted with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the o...

Page 4: ...y Use the correct welding screen and filter lens and wear protective clothing S Protect bystanders with suitable screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore tha...

Page 5: ...ercentage of a ten minute period that you can weld at a cer tain load without overloading Enclosure class The IP code indicates the enclosure class i e the degree of protection against penetration by...

Page 6: ...duty cycle 120A 35 duty cycle 150A 35 duty cycle 10 A 16 A 20 A Mains cable area 3 x 2 5 mm2 Welding cable area 16 mm2 Note The installed plug is approved for max 16A North American version The mains...

Page 7: ...e control unit 8 Indicating lamp green mains power supply 9 Indicating lamp yellow for overheating 6 2 2 Panel function symbols MMA Amp Volt Fj rrdon TIG Hot Start Arc Force 6 2 3 Hidden functions A n...

Page 8: ...ately melts and sticks to the metal rendering continued welding impossible Therefore the arc has to be struck in the same way that you would light a match Quickly strike the electrode against the meta...

Page 9: ...ich menu is displayed This value is displayed in the main menu only 6 6 TIG welding TIG welding melts the metal of the workpiece using an arc struck from a tungsten electrode which does not itself mel...

Page 10: ...arc S Check that the mains power supply switch is turned on S Check that the welding current supply and return cables are correctly connected S Check that the correct current value is set S Check to...

Page 11: ...utton If the fault persists contact a service workshop E10 20V fault 18 5 21 5 V Automatic reset once fault has disappeared E11 15 V fault 13 0 16 0 Automatic reset once fault has disappeared E13 High...

Page 12: ...Diagram 12 CaddyArc150...

Page 13: ...13 CaddyArc150...

Page 14: ...4 bh26o Ordering no Denomination Type 0459 199 880 Welding Power source CaddyArc 150 for 230 V mains voltage 0459 199 886 Welding Power source CaddyArc 150 for 230 V mains voltage North American versi...

Page 15: ...CaddyArc 150 Edition 041101 Spare parts list 15 bh26s Item Qty Ordering no Denomination 101 1 0459 277 001 Filter...

Page 16: ...mote control MMA 1 10 m cable MMA and TIG current 0349 501 024 Foot control FS002 MMA and TIG current 0349 090 886 Remote control unit AT1 MMA and TIG current 0459 491 896 Remote control unit AT1 CF M...

Page 17: ...17 p...

Page 18: ...l AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel 54 11 4 753 4039 Fax...

Reviews: