4 INSTALLATION
0460 826 374
- 10 -
© ESAB AB 2019
4
INSTALLATION
The installation must be carried out by a professional.
NOTE!
Mains supply requirements
This equipment complies with IEC 61000-3-12 provided that the short-circuit power
is greater than or equal to S
scmin
at the interface point between the user's supply
and the public system. It is the responsibility of the installer or user of the equipment
to ensure, by consultation with the distribution network operator if necessary, that
the equipment is connected only to a supply with a short-circuit power greater than
or equal to S
scmin
. Refer to the technical data in the TECHNICAL DATA chapter.
4.1
Location
Position the welding power source such that its cooling air inlets and outlets are not
obstructed.
4.2
Mains power supply
Check that the welding power source is connected to the
correct mains power supply voltage, and that it is protected by
the correct fuse size.
A protective earth connection must be made in accordance with
regulations.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable area
Tig 1500i
Tig 2200i
TIG (GTAW)
MMA (SMAW)
TIG (GTAW)
MMA (SMAW)
Mains voltage
230 V ± 10%, 1~ 230 V ± 10%, 1~ 230 V ± 10%, 1~ 230 V ± 10%, 1~
Mains frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
Mains cable area
mm
2
3G2.5
3G2.5
3G2.5
3G2.5
Phase current I
1eff
9 A
11 A
11 A
14 A
Fuse
anti-surge
16 A
16 A
16 A
16 A
type C MCB
13 A
13 A
16 A
16 A
Summary of Contents for Caddy Tig 1500i VRD
Page 2: ......
Page 17: ...DIAGRAM 0460 826 374 17 ESAB AB 2019 DIAGRAM Tig 1500i TA34 ...
Page 18: ...DIAGRAM 0460 826 374 18 ESAB AB 2019 ...
Page 19: ...DIAGRAM 0460 826 374 19 ESAB AB 2019 Tig 1500i TA33 ...
Page 20: ...DIAGRAM 0460 826 374 20 ESAB AB 2019 ...
Page 21: ...DIAGRAM 0460 826 374 21 ESAB AB 2019 Tig 2200i TA33 TA34 ...
Page 22: ...DIAGRAM 0460 826 374 22 ESAB AB 2019 ...