-- 22 --
bu18d1e
5.4
Mains power supply
Make sure that the welding power source is
connected to the correct supply voltage and that it
is protected by the correct fuse rating.
A protective earth connection must be made in
accordance with regulations.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable areas
AristoMig 320
3
~
50 Hz
3
~
50 Hz
3
~
50 Hz
3
~
60 Hz
3
~
60 Hz
3
~
60 Hz
3
~
60 Hz
Mains voltage V
230
400
500
208
230
460
475
Current A 100%
60%
27
37
16
21
13
15
30
38
27
34.5
13.5
17
13
16.5
Mains cable area
4G10
4G4
4G4
4G10
4G10
4G4
4G4
Fuse anti--surge A
25
16
16
35
25
16
16
AristoMig 450
3
~
50 Hz
3
~
50 Hz
3
~
50 Hz
3
~
60 Hz
3
~
60 Hz
3
~
60 Hz
3
~
60 Hz
Mains voltage V
230
400
500
208
230
460
475
Current A 100%
40
24.5
18.5
45
41
20
19.5
60%
51
30.5
23
57.5
51.5
25
24.5
45%
55.5
34
25
62
56.5
27.5
26.5
Mains cable area
4G10
4G4
4G4
4G10
4G10
4G4
4G4
Fuse anti--surge A
50
20
20
50
50
20
20
Note!
The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. Use the welding power source in accordance with the relevant national regulations.
GB
Summary of Contents for AristoMig 320
Page 2: ...2 Rights reserved to alter specifications without notice 3 ENGLISH 16...
Page 4: ...bu18d1r 4 1 ESAB 1 B S S S S S 2 S S 3 S S 4 S S 5 S S S S RU...
Page 8: ...bu18d1r 8 4 4 1 4 2 4 3 RU...
Page 10: ...bu18d1r 10 4 5 RU...
Page 11: ...bu18d1r 11 4 6 MMC 1 2 5 4 8 8 RU...
Page 14: ...bu18d1r 14 6 1 50 50 6 2 RU...
Page 15: ...bu18d1r 15 7 S S S S S S S S S S S 8 ESAB ESAB ESAB RU...
Page 23: ...23 bu18d1e 5 5 Electrical installation GB...
Page 28: ...Diagram 28 bu18e11a...
Page 29: ...29 bu18e11a...
Page 35: ...35 backpage...
Page 36: ......