7 TROUBLESHOOTING
0460 740 001
- 16 -
© ESAB AB 2017
7
TROUBLESHOOTING
Try these recommended checks and inspections before sending for an authorized service
technician.
Type of fault
Action
No arc.
• Check that the mains power supply
switch is turned on.
• Check that the welding and return cables
are correctly connected.
• Check that the correct current value is
set.
• Check the mains power supply fuses.
The welding current is interrupted during
welding.
• Check whether the overloading protection
has deployed (indicated in the control
panel).
• Check the mains power supply fuses.
The overheating protection trips frequently.
• Check to see whether the dust filter is
clogged.
• Make sure that you are not exceeding the
rated data for the power source (i.e. that
the unit is not being overloaded).
Poor welding performance.
• Check that the welding and return cables
are correctly connected.
• Check that the correct current value is
set.
• Check that the correct wire or electrode is
used.
• Check the mains power supply fuses.
Summary of Contents for Aristo Mig 4001i
Page 2: ......
Page 18: ...DIAGRAM 0460 740 001 18 ESAB AB 2017 DIAGRAM...
Page 19: ...DIAGRAM 0460 740 001 19 ESAB AB 2017...