S0740 800 196/E101019/P76
- 54 -
ca41f2heat
Mounting components on the heat sink
Thermal paste
Apply thermal conducting paste to the components before fitting them to the heat sink.
See the spare parts list for the order number for thermal paste. Use only the paste
recommended by us.
1.
Start by cleaning the heat sink from dirt and old thermal paste.
2.
Apply a
very thin
, even layer of thermal paste to the contact surfaces of the
components.
The purpose of the paste is to fill out any hollows in the surfaces of the components
and the heat sink. Those parts of the component and the heat sink that are in true
metallic contact may already have good thermal contact.
3.
Mount the components as described below.
Rectifier bridge 2BR1
1.
Clean the heat sink and apply thermal conducting paste as described above.
2.
Fit the bridge and tighten the screws to a torque of 1 Nm, and then further tighten them
to 4.5 Nm.
3.
Tighten the screws that connect the bridge to circuit board 2AP1 to 4.5 Nm.
Fitting of rectifier bridge 2BR1 and circuit board 2AP1
Summary of Contents for Aristo Mig 3001i
Page 10: ...S0740 800 196 E101019 P76 Mig 3001i 10 ca41_00 ...
Page 11: ...S0740 800 196 E101019 P76 Placement of the circuit boards Mig 3001i 11 ca41_00 ...
Page 12: ...S0740 800 196 E101019 P76 Tig 3001i Placement of the circuit boards Tig 3001i 12 ca41_00 ...
Page 13: ...S0740 800 196 E101019 P76 13 ca41_00 ...
Page 23: ...S0740 800 196 E101019 P76 15AP1 Component positions 23 ca41_15_1 ...
Page 35: ...S0740 800 196 E101019 P76 20AP1 Component positions version 1 35 ca41_20_1 ...
Page 36: ...S0740 800 196 E101019 P76 20AP1 Component positions version 2 36 ca41_20_1 ...
Page 47: ...S0740 800 196 E101019 P76 Power board 15AP1 measuring points 47 ca41f2pwr ...
Page 49: ...S0740 800 196 E101019 P76 49 ca41f2pwr Secondary board 15AP2 measuring points ...
Page 53: ...S0740 800 196 E101019 P76 Soft starting measuring points power board 15AP1 53 ca41f2soft ...