5 MAINTENANCE
0443 408 101
- 10 -
© ESAB AB 2021
5
MAINTENANCE
• Empty all flux from the flux tank when not being used for welding. Flux absorbs
moisture from the air.
• When emptying the tank use the minimum air pressure necessary to avoid blasting flux
out of the tank.
• Keep the work area free from dust and flux by cleaning regularly.
• Replace the flux hose when it becomes worn.
• Check the water trap daily to monitor compressed air quality. If water is present it may
be necessary to install a dehumidifier.
NOTE!
Pressure vessels used for flux distrubution should be inspected for renewed approval