ACTION:  

 

1.  Remove the Main Control PCB from the power source. 
2.  Solder the positive (+) lead of the 22 microfarad electrolytic capacitor to the banded (+) 

end of diode D46. See photo below. 

3.  Solder the negative (-) lead to the end of R159 that is the emitter lead of transistor Q30 

& Q31. 

4.  Re-install control PCB into power source. 

 

 
 
 

         

              

 

-

22 microfarad 50 vdc 

capacitor  PN -951013 

+

-

+

 
 
 
 
 

 

 
 
 

 