ACTION:
1. Remove the Main Control PCB from the power source.
2. Solder the positive (+) lead of the 22 microfarad electrolytic capacitor to the banded (+)
end of diode D46. See photo below.
3. Solder the negative (-) lead to the end of R159 that is the emitter lead of transistor Q30
& Q31.
4. Re-install control PCB into power source.
-
22 microfarad 50 vdc
capacitor PN -951013
+
-
+
CONTACT:
ESAB Welding & Cutting Products
Product & Service Information Group
843-664-4416 Phone
843-664-5539 FAX