4 INSTALLATION
0463 283 001
- 13 -
© ESAB AB 2013
Connection instruction
The power source is connected to 400V from factory. If another mains voltage is required, the
cable on the printed circuit board has to be moved and placed on the correct pin. See picture
above. This operation has to be made by persons who have appropriate electrical
knowledge.
Change of mains cable
If the mains cable needs to be changed, the earth connection to the bottom plate must be
made in a correct way. See from the picture above in which order the washers, nuts and
screws are placed.