![ESAB 0401510 User Manual And Spare Parts Download Page 18](http://html1.mh-extra.com/html/esab/0401510/0401510_user-manual-and-spare-parts_2424862018.webp)
6 INSTALLATION
are a three-phase welding rectifier, to be connected across three input phases. The mains cable
is connected to the circuit breaker. The primary connections are reconnectable for different input voltages
(220, 380 or 440 V - 60Hz or 380 V -50 Hz). The picture 6.3 shows the different voltage connections
procedures. Remove the cover on the left panel and reconnect the terminal block as shown on the electric
diagram.
Recommended cable areas and fuses ratings are listed below.
Connected the rectifier across three input phases and ground connection according to regulations.
Origo Arc
TM
IMPORTANT!
:
The grounding terminal is connected to the rectifier chassis. It
must to be connected to an efficient grounding point to the general power
supply system.
18
TABLE 6.1
380V 50Hz
01
02
440V 60Hz
380V 60Hz
220V 60Hz
01
02
01
01
02
440V 60Hz
440V 60Hz
02
Note: wires 01 and 02 for fan
Picture 6.3
TABLE 6.1
406
90
54
47
44
256
62
35
29
28
256
70
40
35
30
406
100
63
50
50
456
120
70
63
50
16,0
10,0
10,0
10,0
220/60
380/60
440/60
380/50
Power
Supply
( V/Hz )
Current (A)
Wire
( copper - mm )
2
Fuse
delay ( A )
426
93
58
40
44
426
100
63
50
50
456
110
62
55
47
Summary of Contents for 0401510
Page 9: ...9 p gina intencionalmente em branco...
Page 10: ...10 p gina intencionalmente em branco...
Page 12: ...12 p gina intencionalmente em branco...
Page 22: ...22 intentionally blank page...
Page 32: ...32 p gina intencionalmente en blanco...
Page 49: ...49 p gina intencionalmente em branco...
Page 52: ...52 p gina intencionalmente em branco...