8) MAINTENANCE AND SERVICE
The rectifiers require a minimum of maintenance. Under normal conditions, it is sufficient to blow the
rectifier clean with dry compressed air with reduced pressure once a year. If used in dusty and dirty areas, it
must be cleaned more often.
Spare parts, see pages
,
for the rectifiers can be ordered from your local
representative.
35, 36, 37, 38 and 39
10) ACESSORIES
TABLE 9.1
Description
Electrode holder and work clamp
Digital Volt/Amp Meter
Reference
0400257
0401306
9) ELETRICAL DIAGRAM
See page 34.