ESA 125T Owner'S Manual Download Page 7

113170-01E 

7

 

www.desatech.com

 

 

 

OPERATION

 

Continued

 

RL, RE AND PKHD SERIES MODELS 
ONLY

 

Temperature Display

 

These  models  are  equipped  with  a  digital  tem- 
perature  display.  The  temperature  being  shown 
represents the air nearest to the control cover. The 
temperature of the air in surrounding areas may 
be  much  different  from  the  temperature  being 
displayed. The display may show [ - - ] when the 
thermostat control or temperature sensor are dis- 
connected from the ignition control or if they are 
or damaged. If this occurs, the safety control will 
continue to operate as before, however, the unit 
will not cycle off during operation. See Figure 4.

 

 

Lighted ON/OFF

 

Switch                                    

Thermostat

 

Control

 

 

 

 
 
 

 

Temperature 
Display

 

LED Indicator Lights

 

These models are equipped with LED lights in order 
to help monitor your heater and to help diagnose 
any potential problems associated with your heater. 
Make sure you have read all of the instructions and 
see 

Troubleshooting

, page 8, before attempting to 

rectify any problems with your heater.

 

 

WARNING:  Never  service 

heater  while  it  is  plugged  in, 
operating or hot. Severe burns 
and electrical shock can occur.

 

 

LOGIC ENHANCED IGNITION

 

These  models  have  an  electronically  controlled 
ignition  system  that  is  able  to  detect  problems 
during startup and is able to apply an automatic 
“choke” to increase the likelihood of ignition. If 
the heater does not ignite within the first second 
the  motor  will  slow  down  momentarily.  If  your 
heater does not light after the first “choke” it will 
repeat once. If the heater does not ignite after the 
second  “choke”  it  will  shutdown  and  remain  in 
shutdown mode until the unit is reset. Please refer 
to 

Troubleshooting

,  page  8  in  order  to  properly 

diagnose the problem.

 

 

Figure 4 - Control Cover with 

Temperature Display

 

 

Ignitor 

-  indicates  a  problem  with 

the  ignitor  and  can  be  caused  by 
a  damaged  or  broken  ignitor  or  an 
ignitor that is wired incorrectly.

 

 

 
 

Flame 

- will illuminate after heater 

is  shut  down  due  to  problems 
associated  with  the 

flame  or  the 

photocell that monitors the flame.

 

 

4

 

 

5

 

Temperature 
Temperatura

 

6

 

 

 

LO      Thermostat

 

Termostato

 

HI

 

 

112935-01

 

 

Temperature 
Display

 

 

Voltage 

- monitors line voltage during 

normal  operation  and  indicates 
improper  line  voltage.  If  line  voltage 
falls  below  108V  or  above  132V  the 
heater will shut down.

 

 

Start/Run 

-  blinks  during 

“preheat”  for  10-15  seconds 
before ignition and will stay on 
during normal operation.

 

Figure 5 - LED Indicator Lights

 

Summary of Contents for 125T

Page 1: ...ct Identification 3 Theory of Operation 4 Ventilation 4 Assembly 4 Operation 5 Operation with Portable Generator 7 Storing Transporting or Shipping 7 Preventative Maintenance Schedule 8 Troubleshooting 8 Service Procedures 10 Specifications 15 Wiring Diagrams 16 Technical Service 17 Replacement Parts 17 Accessories 17 Illustrated Parts Breakdown and Parts List 18 Warranty and Repair Service 28 Fill ...

Page 2: ...include pregnant women persons with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this heater 1 Use only kerosene 1 2 diesel fuel oil JET A or JP 8 fuels to avoid risk of fire or explosion Never use gasoline naphtha pain...

Page 3: ... combustible materials 8 feet 244 cm from hot air outlet 6 feet 183 cm from top and 4 feet 120 cm from sides and inlet 7 Locate heater on a stable and level surface while hot or operating or a fire may occur 8 Use only in well vented areas Before using heater provide at least a 2800 square cm three square foot opening of fresh outside air for each 30 kw 100 000 Btu Hr of rating 9 Keep children and ...

Page 4: ...is damaged promptly inform dealer where you bought heater FUELS WARNING Use only kero sene 1 2 diesel fuel oil JET A or JP 8 fuels to avoid risk of fire or explosion Never use gasoline oil drained from crankcases naphtha paint thinners alcoholorotherhighly flammable fuels Use only kerosene 1 2 diesel fuel oil JET A or JP 8 fuels Heavier fuels such as No 2 fuel oil or No 2 diesel fuel may also be use...

Page 5: ...ir if more heaters are being used The minimum ventilation requirements must be followedtoavoidrisksassociated withcarbonmonoxidepoisoning Make certain these requirements are met prior to operating heater Example A 58 6 kw 200 000 Btu Hr heater requires one of the following a two car garage door 4 88 meter 16 feet opening raised 12 7 cm 5 inches a single car garage door 2 74 meter 9 feet opening ra...

Page 6: ...d three wire extension cord Extension cord must be at least six feet 1 8 meters long Extension Cord Size Requirement 6 to 10 feet 1 8 to 3 meters long use 18AWG 0 75 mm2 rated cord 11 to 100 feet 3 3 to 30 5 meters long use 16 AWG 1 0 mm2 rated cord 101 to 200 feet 30 8 to 61 meters long use 14 AWG 1 5 mm2 rated cord 6 Plug extension cord into standard 120 volt 60 hertz 3 prong grounded outlet 7 T...

Page 7: ...hock can occur LOGIC ENHANCED IGNITION These models have an electronically controlled ignition system that is able to detect problems during startup and is able to apply an automatic choke to increase the likelihood of ignition If the heater does not ignite within the first second the motor will slow down momentarily If your heater does not light after the first choke it will repeat once If the heat...

Page 8: ... the generator Refer to Operation page 5 for starting stopping and resetting heater procedures Alternator STORING TRANSPORTING OR SHIPPING Note If shipping transport companies require fuel tanks to be empty 1 Remove drain plug from bottom side of fuel tank and drain all fuel 2 Replace drain plug 3 If any debris is noted in old fuel add 1 or 2 quarts of clean kerosene to tank stir and drain again T...

Page 9: ...ubricated TROUBLESHOOTING WARNING Never service heater while it is plugged in operating or hot Severe burns and electrical shock can occur FAULT CONDITION Motor does not start five seconds after heater is plugged in INDICATOR LIGHT Ignitor POSSIBLE CAUSE 1 No power to heater 2 ON OFF switch not in the ON position 3 Thermostat setting is too low REMEDY 1 Check circuit breaker in elec trical panel 2 ...

Page 10: ...08V or 9 Check for proper line voltage above 132v Heater ignites but ignition control assembly shuts heater off after a short period of time INDICATOR LIGHT Flame 1 Pump pressure incorrect 1 See Pump Pressure Adjust ment page 10 2 Dirty air intake air output 2 See Air Output Air Intake and and or lint filter 3 Dirty fuel filter 4 Obstruction in nozzle Lint Filters page 10 3 See Fuel Filter page 11 4...

Page 11: ...tput Air Intake and Lint Filters IMPORTANT Remove fan from motor shaft before removing motor from heater The weight of the motor resting on the fan could damage the fan pitch see Figure 8 1 Remove upper shell see Figure 7 2 Use 1 8 allen wrench to loosen setscrew which holds fan to motor shaft 3 Slip fan off motor shaft 4 Clean fan using a soft cloth moistened with kerosene or solvent 5 Dry fan th...

Page 12: ......

Page 13: ... 12 Adjusting Pump Pressure FUEL FILTER 1 Unplug heater 2 Remove control cover screws using medium phillips screwdriver 3 Remove control cover 4 Pull upper fuel line off fuel filter neck see Figure 13 5 Carefully pry bushing fuel filter and lower fuel line out of fuel tank see Figure 13 6 Wash fuel filter with clean fuel and replace in Figure 14 6 Remove combustion chamber Stand com bustion chamber o...

Page 14: ...12 113170 01E www desatech com Figure 14 Disconnecting Ignitor Wires from Ignition Control Assembly 170T Model Shown ...

Page 15: ...fuel line hose and air line hose to nozzle adapter assembly See Fuel and Air Line Replacement and Proper Routing page 13 14 Replace photocell in photocell bracket Route wires as shown in Figure 17 Figure 16 Ignitor HA1100 Replacement NOZZLE ASSEMBLY 125T and 170T Models Only 1 Remove upper shell see Upper Shell Re moval page 10 2 Remove fan see Fan page 10 3 Remove fuel and air line hoses from noz...

Page 16: ...14 113170 01E www desatech com Assembly ...

Page 17: ...Replace fan see Fan page 10 13 Replace upper shell see Upper Shell Removal page 10 Nozzle Face Nozzle Sleeve Nozzle Face Nozzle Nozzle Adapter Nozzl e Sleev e Nozzle Adapter Nozzle Adapter Bracket Air Line Fitting Fuel Line Fitting Nozzle Air Line Fitting Fuel Line Fitting Figure 19 Nozzle and Nozzle Adapter 200T Model Only 1 Remove combustion chamber and ignitor by following steps 1 through 7 und...

Page 18: ...igure 20 according to model and from fuel filter see Fuel Filter page 11 If air line hose is damaged disconnect from nozzle adapter see Figure 17 page 12 or Figure 20 according to model and from barb fitting on pump end cover see Figure 22 page 14 5 Install new air and or fuel line Attach one end of air line hose to barb fitting on pump end cover see Figure 22 page 14 and the other end to nozzle adap...

Page 19: ...004 if needed see Figure 24 Note Rotate rotor one full turn to ensure the gap is 076 101 mm 003 004 at tightest position Adjust if needed 11 Install blades pump plate air filters and filter end cover 12 Replace fan guard and upper shell see Upper Shell Removal page 10 13 Adjust pump pressure see Pump Pressure Adjustment page 10 With Feeler Gauge Rotor Blade Gap Adjusting Screw Figure 24 Gap Adjustin...

Page 20: ... 0 6 2 Electric Requirements 120 V 60 HZ 120 V 60 HZ 120 V 60 HZ Amperage Normal Run 3 6 3 6 3 6 Maximum Motor Speed RPM 3400 3400 3400 Hot Air Output CFM 520 580 600 Motor Horsepower 1 5 1 5 1 4 Shipping Weight 81 36 74 82 37 2 87 39 46 Approximate Pounds Kilograms Heater Weight without Fuel 73 33 11 74 33 57 79 35 86 Approximate Pounds Kilograms Use of 2 diesel fuel oil will result in noticeable...

Page 21: ...113170 01E 1 9 www desatech com ...