21
Operating Altitude
7000ft. (2000meters) maximum.
Weight
0.753lb (342g) (includes holster).
Size
7.36” x 3.2” x 2.0” (187 x 81 x 50mm)
(includes holster)
Safety
This meter is intended for origin of
installation use and protected by double
insulation per EN61010-1 and IEC61010-1
2
nd
Edition (2001) to Category IV 600V and
Category III 1000V; Pollution Degree 2.
The meter also meets UL 61010-1, 2
nd
Edition (2004), CAN/CSA C22.2 No.
61010-1 2
nd
Edition (2004), and UL
61010B-2-031, 1
st
Edition (2003)
TROUBLE-SHOOTING
1.
METER WILL NOT TURN ON:
Check the battery contacts for a tight fit.
Check for a minimum battery voltage of 8.0 volts.
2.
AMPERE READING IS ERRATIC OR THERE IS NO READING AT ALL:
Disassemble the meter back cover as per the fuse
replacement instructions on page 36 and test the fuses for
continuity with another meter.
3.
METER READING IS ERRATIC:
•
Printed circuit board damaged from handling with hands.
Low battery.
“Blown” fuse.
Open circuit in a test lead (frayed or broken wire).
4.
METER READINGS DO NOT CHANGE:
“Hold” feature is still toggled ON.
TECHNICAL HOTLINE:
800-227-1603
For any technical assistance or possible service issues, please call
the toll free number above. Especially if you feel the need to return
your instrument. Please call us first and let us help you!