____________________MOUNTING INSTRUCTIONS________________
NOTE:
Attachment is shipped with 12FJX (1-
1/16” Female JIC Swivel) fittings on the ends of
the lead hoses.
7. Connect the hydraulic quick couplers from
the snowblower to the loader.
IMPORTANT: Wipe the ends of the hydraulic
quick couplers (both lead and loader) with a
rag to remove any possible contamination.
Contamination can cause hydraulic
components to fail and is not covered under
warranty.
NOTE:
Make sure the pressurized hose is
routed to the “P” port of the valve block. If it
isn’t, the blower will not operate properly.
NOTE:
The pressure line on the snowblower has
a RED cable tie on the hose end.
IMPORTANT:
Make sure the quick couplers
are fully engaged. If the quick couplers do
not fully engage, check to see that the
couplers are the same size and brand. Do
not force the quick couplers together.
NOTE:
If the quick couplers will not connect
together due to thermal expansion of the fluid in
the hoses, stop the engine and activate the
auxiliary hydraulic control to relieve the pressure.
See loader operator’s manual for details on
identifying the correct pressurized hydraulic
coupler.
If you are operating the loader controls correctly
and the snowblower still does not work, try
switching the hydraulic couplers around on the
snowblower lead hoses. This will effectively
reverse the flow to the motor.
14