background image

                                                                                    

AK3000 

– User Manual

 

 

 

By means of the 

or

 we can set the first flashing digit of the

 PIN xxxx 

and by 

ENTER 

button we confirm it. So we can 

enter rest of the PIN. With 

ENTER 

button we can get to the frame 2.8.1.1. :  

 

 

 

 

 

Using buttons 

▲ 

or

 

 we can choose required parameter then by means of 

ENTER 

button confirm and flashing parameter 

is able to change by 

▲ 

or

 

 buttons: 

 

 

......

 

 

Frame 2.8.1.1 we can leave by click of the 

 ( ESC ). Parameter is set now.

 

 

Boiler type. Numeric value represents power of the boiler and L character 

is for Lambda module connected.  

 Caution! Parameter setup can 

change related parameters.

 

XY16, XY16L,....XY100, 

XY100L etc. 

 

 

Main fan is suction type. We can change it to the blower type. 

  or  

 

 

Combustion thermometer is installed. 

Boiler reaches END status after 

decreasing the combustion temperature below  

 

end 

value. 

 

yes / no 

 

Auxiliary fan is not connected.  

yes / no 

 

Boiler thermometer is installed with KTY type. You can change it to the Pt1000. 

KTY / Pt1000 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AK 6000

Page 1: ...AK 6000 Maga Wood Gasifying Boilers Control System User Manual Elektronick riadiace syst my s r o Polianky 18 841 01 Bratislava www ers sk email ers ers sk Tel 421 2 693 07 000...

Page 2: ...cation X means hardware version of the AK6000 where X may be within 0 3 DUOLED Double color light emitting diode used to show main state of the boiler Display Grafic LCD display with 128x64 pixel LED...

Page 3: ...from the AC outlet Do not operate the boiler unless all enclosure panels are properly in place In case of failure detection or damaging any part is important o do not touch any part of boiler o immedi...

Page 4: ...an and auxiliary fan Duo LED red green Water pump output 20 pin connector to connect power board Four temperature sensors T1 T4 Two independent fuses F1 2 0 8A save system parts and fans in malfunctio...

Page 5: ...uply ending after fuel suply is passed by menu level or choice confirmation data storage o long 2 sec pressing entrance to user operation settings button decreasing adjusted value or switching depicti...

Page 6: ...red to fuel supply by means of the double pressing of the ENTER function main fan goes to 100 top speed in suction version or to 0 in blower version Combustion Continuous regulation of the fan keeps t...

Page 7: ...Wait 10 seconds after door is depicted on the display fan will absorb the combustion Open the door and make all required action Short press the ENTER boiler gets in original state again End of the co...

Page 8: ...ton ENTER two seconds long Basic view goes to the frame 1 where we use short click on the ENTER and we are in the frame 1 1 Short click of the ENTER and we can set required temperature by buttons or i...

Page 9: ...uel burnout It keeps the embers waiting 50 130 C Main fan power change For example value 3 decreases fan speed in 30 3 2 2 3 Fan minimal speed This value is limit for speed decrease of the fan after r...

Page 10: ...leave by double click of the ESC All the connected accsesories are monitored by system Common error status is displayed by red color of the LED More exactly is error message displayed on the LCD displ...

Page 11: ...e by triple click of the ESC We can use service parameter setup 1 to configurate basic properties of the connected components Improper setup of service parameters can result in risk of boiler incorrec...

Page 12: ...1 we can leave by click of the ESC Parameter is set now Boiler type Numeric value represents power of the boiler and L character is for Lambda module connected Caution Parameter setup can change relat...

Page 13: ...e now A frame with request for service PIN will be displayed By means of the or we can set the first flashing digit of the PIN yyyy and by ENTER button we confirm it So we can enter rest of the PIN Wi...

Page 14: ...hing digit of the PIN xxxx and by ENTER button we confirm it So we can enter rest of the PIN With ENTER button we can get to the frame 2 8 Subsequently by means of the and ENTER button we can depict f...

Page 15: ...re range max 45 C Case IP00 Component terminals Fan Pump 0 75mm T1 T4 0 5 mm Maximum number of inputs 3 Boiler thermometer KTY PTC polovodi R 2kOhm 20 C Combustion thermometer PT1000 Crash thermostat...

Page 16: ...AK3000 User Manual BLOCK DIAGRAM AK6000 X...

Reviews: