background image

7

   

*: If hydraulic operators with absorbers are used, soft stop is carried out mechanically by the operator (DIP8 = OFF)

Using radio cards

This control board is factory set to use a two-channel receiver (e.g. IRRE2). This factory setting is modified if an RSD receiver is used and a 
permanent code is recorded (decoding through the board, DIP1 + DIP4 or DIP6 = ON). To recover the factory settings, insert the IRRE2 card 
and place DIP1 + DIP4 or DIP6 = ON. Then return the DIPs to their previous position.

Total opening radio code programming (with RSD receiver only)

If a receiver other than RSD is used,
see the corresponding instructions.

                                                                    

 1 

Connect the electrical power

supply and close the leaf, keeping
PUL1 pressed down.

                                                                     

 2 

Select the code in the transmitter.

 3 

Place the DIPs as shown in the

figure (DIP1=ON, DIP4=ON). DL3
lights up to show programming mode
enabled.

                                                                         

 4 

Press the button of the required

channel. DL2 flashes to show
programming is complete.

 5 

Place DIP1 and DIP4 in OFF.

DL3 remains off. 

                                                                   

 6 

Disconnect and reconnect the

electrical power supply.

                                                                    

Programming is carried out in the
same way, using DIP6 instead of DIP4.

R175B

R175K

Pedestrian opening radio 

code

Total open/close programming

 1 

Connect the electrical power supply

and close the leaf, keeping PUL1
pressed down.

                                                                     

 2 

Place DIP1 in ON, DIP2 in ON, DIP5

in ON (only with electrolock), DIP8 in
ON (soft stop)*. 

DL3 lights up (programming enabled).
                                                                       

 3 

Press ST1 to start opening the leaf.

 4 

Press ST1 to start soft stop (with

DIP8=ON only).

                                                                       

 5 

Press ST1 to finish opening (if FCA

is installed, it is not necessary to press
ST1).

                                                                     

 6 

Press ST1 to start closing the leaf

 7 

Press ST1 to start soft stop (with

DIP8=ON only).

                                                                      

 8 

Press ST1 to finish closing (if FCC is

installed, it is not necessary to press
ST1). 

                                                                      

 9 

 Place DIP1 and DIP2 in OFF. DL3

remains off.

Pedestrian open/close programming

This is carried out in the same way as total open/close
programming, with the following differences:

DIP1 and DIP3 are used instead of DIP1 and DIP2

ST2 is used instead of ST1

Summary of Contents for VIVO-M101

Page 1: ... continuous improvement the firmware is subject to the incorporation of new functionalities or their extension and consequently to the generation of new versions not necessarily compatible with the previous ones Therefore if your firmware version is lower than the one indicated in this guide some options and functions may not be available or may be different E175A ELECTRICAL CABLING Element Nº wir...

Page 2: ... or partially open DL1 DL3 flashing STOP contact open emergency stop activated DL2 Receiving RSD plug in receiver radio signal RUN OK DL3 Radio code or operation programming DL4 Opening relay activated DL5 Closing relay activated DL6 Interior safety device contacts FT2 closed DL7 FCA contacts closed DL8 FCC contacts closed DL9 Exterior safety device contacts FT1 closed DL10 Pedestrian key command ...

Page 3: ...DL2 flashes to show programming is complete 5 Place DIP1 and DIP4 in OFF DL3 remains off 6 Disconnect and reconnect the electrical power supply Programming is carried out in the same way using DIP6 instead of DIP4 R175B R175K Pedestrian opening radio code Total open close programming 1 Connect the electrical power supply and close the leaf keeping PUL1 pressed down 2 Place DIP1 in ON DIP2 in ON DI...

Page 4: ... obstacle detection the obstacles are only detected when the gate has come to a complete halt ON Function activated during quick travel the gate detects obstacles upon collision and recedes when soft stop is activated DIP8 ON or remains shut down when soft stop is disabled DIP8 OFF in order to prevent crushing OFF Function disabled DIP10 Dead man function Only with DIP4 OFF and DIP11 OFF ON Dead m...