background image

7

  

Turning direction:

 check operation using the OPEN and CLOSE connectors. 

If turning direction is not correct, interchange the motor cables connected to cable connectors MOT1 and MOT2. 

Turning direction check

Total opening radio code programming

 1 

Connect the electrical power
supply. 
Press S1 and keep it pressed down
for around 2 seconds, until the
“LEARN” LED comes on.
Release S1 when “LEARN” comes
on.

 2 

Press the transmitter button to be
programmed while "LEARN" is on
(any of the three transmitter
channels can be used). 

“LEARN” will go off after 2
seconds, indicating that
programming is complete.

  

S1

LEARN

2s

S1

LEARN

S1

LEARN

S1

LEARN

R287B

S1

LEARN

2s

Pedestrian opening radio code

Pedestrian opening is carried out with the fourth channel button, although it
does not need to be programmed: when programming total opening (buttons
1, 2 or 3), number 4 is automatically assigned to pedestrian opening.

R287C

Carry out the same process to programme more transmitters if required.
The memory can be used with up to 25 transmitters.

Deleting all the transmitters

 1 

Connect the electrical power supply.

 2 

Press S1 until the “LEARN” LED comes on, without
releasing it. Keep S1 pressed down until “LEARN” goes
off, and then release it. All the transmitters will be
deleted.

S1

LEARN

R287D

2s

S1

LEARN

S1

LEARN

S1

LEARN

Programming the run

The operator automatically programmes the complete
run during the first operation. To ensure programming
is correct, the magnetic limit switches must be installed
and correctly adjusted in their definitive positions.
Maximum run: 12 m.

Pedestrian opening is 1 metre. This distance is
programmed as default and cannot be changed.

Summary of Contents for CAT

Page 1: ...r upgrades being included as a result of new versions which are not necessarily compatible with previous ones For this reason some options or functions may differ or be unavailable if your firmware is older than shown in this guide 90º 90º D287A 90 135 200 5 130 200 FCC FCA E287C Assembly levels mm Manual operation Motorised operation locking Proceed in reverse order to release Move the gate manua...

Page 2: ... F1 10A fuse Ensure the power supply is disconnected before making or changing the connection When the connections are complete return the control panel cover The panel has a built in radio receiver RSD to receive transmitter signals at 433 92MHz Connectors CLOSE 1 Close Pushbutton OPEN 2 Open Pushbutton STOP 3 Stop Pushbutton COM 4 Pushbutton Common A T 5 Total Opening Pushbutton A P 6 Pedestrian...

Page 3: ...he fourth channel button although it does not need to be programmed when programming total opening buttons 1 2 or 3 number 4 is automatically assigned to pedestrian opening R287C Carry out the same process to programme more transmitters if required The memory can be used with up to 25 transmitters Deleting all the transmitters 1 Connect the electrical power supply 2 Press S1 until the LEARN LED co...

Page 4: ...can be adjusted using this potentiometer Turning the potentiometer clockwise decreases sensitivity turning it anti clockwise increases it VR2 Braking time The motor is used to brake at the end of the operation thus offsetting the inertia of the gate when braking Adjust the potentiometer to ensure proper braking Turning the potentiometer clockwise increases the force turning it anti clockwise decre...

Reviews: