7
Turning direction:
check operation using the OPEN and CLOSE connectors.
If turning direction is not correct, interchange the motor cables connected to cable connectors MOT1 and MOT2.
Turning direction check
Total opening radio code programming
1
Connect the electrical power
supply.
Press S1 and keep it pressed down
for around 2 seconds, until the
“LEARN” LED comes on.
Release S1 when “LEARN” comes
on.
2
Press the transmitter button to be
programmed while "LEARN" is on
(any of the three transmitter
channels can be used).
“LEARN” will go off after 2
seconds, indicating that
programming is complete.
S1
LEARN
2s
S1
LEARN
S1
LEARN
S1
LEARN
R287B
S1
LEARN
2s
Pedestrian opening radio code
Pedestrian opening is carried out with the fourth channel button, although it
does not need to be programmed: when programming total opening (buttons
1, 2 or 3), number 4 is automatically assigned to pedestrian opening.
R287C
Carry out the same process to programme more transmitters if required.
The memory can be used with up to 25 transmitters.
Deleting all the transmitters
1
Connect the electrical power supply.
2
Press S1 until the “LEARN” LED comes on, without
releasing it. Keep S1 pressed down until “LEARN” goes
off, and then release it. All the transmitters will be
deleted.
S1
LEARN
R287D
2s
S1
LEARN
S1
LEARN
S1
LEARN
Programming the run
•
The operator automatically programmes the complete
run during the first operation. To ensure programming
is correct, the magnetic limit switches must be installed
and correctly adjusted in their definitive positions.
Maximum run: 12 m.
•
Pedestrian opening is 1 metre. This distance is
programmed as default and cannot be changed.