![Erreka ABC2M-009 Installer Manual Download Page 45](http://html1.mh-extra.com/html/erreka/abc2m-009/abc2m-009_installer-manual_2424273045.webp)
DESCRIPTION OF THE PRODUCT
Descripción_1
3_v1.
0.fm -
16/4/08
Control panel ABC2M-009
41
Operation pre-warning function (DIP2)
This function delays the start of operation by three
seconds, during which time the flashing lamp comes on
to warn us that operation is about to begin.
DIP2=ON:
three seconds warning
DIP2=OFF:
no warning
Movement to original position
When connecting the control panel, or when the
electrical supply is restored following interruption, the
leaves move to their original position: first leaf 2 is
closed, followed by leaf 1, at slow speed, through to
the in-ground stop in closing. The control panel thus
stores the closing position.
The flashing lamp, the SCA lamp and the garage
lighting remain off during movement to original
position.
3
OPENING MODES
The opening operation starts up in all cases by operating the corresponding transmitter (magnetic key, key selector,
remote control, etc).
Step-by-step mode (DIP3 ON)
If, during the opening, the corresponding transmitter is
operated, the gate stops. The gate closes when
operated again.
Community mode (DIP3 OFF)
During opening, the control panel does not obey the
transmitter orders.
4
CLOSING MODES
The closing mode can be selected by way of programming.
Semiautomatic mode (DIP4 OFF)
Wait:
The gate remains open indefinitely until the push
button or remote control is operated.
Close:
The closing process starts up by operating the
corresponding transmitter.
If, during the closing, the transmitter is operated, the
gate inverts the operation direction and it opens
completely.
Automatic mode (DIP4 ON and DIP6 OFF)
Wait
: The gate remains open during the programmed
time.
If, during the waiting time, the transmitter is
operated, the waiting time restarts.
Waiting time only starts once the photocells indicate
free passage. If, during waiting, the photocells are
operated, the waiting time restarts.
Close:
The closing operation starts once waiting time is
finished.
If, during the closing, the push button or the remote
control is operated, the gate inverts the operation
direction and it opens completely.
Optional Automatic Mode (DIP4 ON and DIP6 ON)
Wait:
The gate remains open during the programmed
time.
If, during the waiting time, the transmitter is operated, the
gate begins to close after 3 seconds of waiting.
If, during waiting, the photocells are operated, the
waiting time concludes when the obstacle disappears,
and the gate begins to close after a few moments.
Close:
The closing operation starts once waiting time is
finished.
If, during the closing, the corresponding transmitter
is operated, the gate inverts the operation direction
and it opens completely.
ABC2M-009_ES_FR_EN_PT_DE.book Page 41 Thursday, April 17, 2008 9:43 AM