Erone SEL2641R433-P4 Use And Installation  Manual Download Page 3

230 V

P

N

C

OUV/FERM

M

6

5

4

3

2

1

ON

ON

1 2 3 4 5 6

3

4

5

ON

Fig. 2

Trasformatore di alimentazione

Transformer

Transformateur

Trasformator

Tasto PV - 

 LV

Push-button PV - LED LV
Touche PV - LED LV
Taster PV - LED LV

LED

Dip-switch 6 vie

Dip-switch 
Dip-switch

Dip-switch zur programmierung

Fusibile F1 : 3,15A - 250V
Fuse F1 : 3,15A - 250V
Fusible F1 : 3,15A - 250V
Sicherung F1 : 3,15A - 250V

Morsettiere di I/O

Terminal boards

Bornes

Anschlüsse

Led L1 : Contatto NA esterno
Led L1 : NO external command
Led L1 : Contact NO exterieur
Led L1 : Sicherheitsvorrichtung

52

140

115

128

104

Tasto PR - 

 LR

Push-button PR - LED LR
Touche PR - LED LR
Taster PR - LED LR

LED

Fig. 3

Fig. 4 

S1 ON = 6 sec. 
S2 ON = 12 sec. 
S3 ON = 24 sec. 
S4 ON = 46 sec.
S5 ON = 96 sec.

S6 ON = Sequenziale / Sequential mode / sequentiel / sequenziell
S1, S2, .., S5 ON / S6 OFF : Misto / Mixed / Mixte / gemischter Betrieb
S1, S2, .., S6 OFF = Uomo Presente / Man present / homme mort / Totmannschaltung

Pag. 3

Dimensioni d’ingombro / Overall dimensions Dimensions 

d’encombrement / Abmessung

Interassi / Drilling distances 

Distances de perçage / Spurweiten

Layout

Arbeitszeiten

OFF

1  ON  6 sec
2  ON  12 sec
3  ON  24 sec
4  ON  46 sec
5  ON  96 sec

F1

1
Ph

2

N

C

O F

6

7

PV

LV

Mode

8

9 10 11

LR

PR

Summary of Contents for SEL2641R433-P4

Page 1: ...e 400W Radioprogrammer 400W R cepteur s quentiel 400W Funkmotorsteuerung 400W Manuale d installazione ed uso Italiano Pag 4 Use and installation Manual English Pag 7 Notices d installation et utilisat...

Page 2: ...nible l adresse internet suivante www erone com Declaration of Conformity SEL2641R433 P4 SEL39R433 P4 SEL39R30 P4 SEL2641R433 P4 SEL39R433 P4 SEL39R30 P4 SEL2641R433 P4 SEL39R433 P4 SEL39R30 P4 SEL264...

Page 3: ...L1 Contact NO exterieur Led L1 Sicherheitsvorrichtung 52 140 115 128 104 Tasto PR LR Push button PR LED LR Touche PR LED LR Taster PR LED LR LED Fig 3 Fig 4 S1 ON 6 sec S2 ON 12 sec S3 ON 24 sec S4 O...

Page 4: ...ingresso 115 117 dBm Emissione dell oscillatore locale 57 dBm Tensione di alimentazione 230 Vac Potenza massima del motore 400 W Capacit di memoria 100 Temperatura di funzionamento 20 70 C Grado di p...

Page 5: ...mando locale prioritario sul comando generale Comando generale E necessario disporre di un trasmettitore a 4 canali della stessa gamma I trasmettitori memorizzati su PV permettono di lavorare in modo...

Page 6: ...i corrispondenza indica la quantit di trasmettitori memorizzati Verifica della posizione di un codice trasmettitore in memoria Premere sul pulsante del radiocomando che si desidera controllare e rilas...

Page 7: ...tivity 115 117 dBm Local oscillator emissions 57 dBm Power voltage 230 Vac Motor maximum power 400 W Memory capacity 100 Operating temperature 20 70 C IP grade IP44 Weight 380 gr Overall dimensions 14...

Page 8: ...llow to operate in sequential mixed or man present mode and by pushing only one key of the transmitter for all the movements opening stop and closing General command It is necessary to have a 4 keys t...

Page 9: ...The final number is equal to the total number of codes stored in the memory Check of the transmitter position inside the memory Push and release the transmitter button for which it is necessary the ch...

Page 10: ...emp rature op rante 20 70 C Indice de protection IP44 Poids 380 gr Dimensions mm 140 x 115 x 52 3 FONCTIONNEMENTS S quentiel 1 impulsion provoque l ouverture 1 impulsion provoque la fermeture arr t su...

Page 11: ...r l ouverture une touche canal D pour la fermeture et un touche canal C pour l arr t En cours de travail ouverture ou fermeture seule la touche arr t est active Pour obtenir un inversement de mouvemen...

Page 12: ...pas de contr ler si un code a t m moris plus d une fois En cons quence il faut consid rer que si un metteur est enregistr deux fois ou plus il est n cessaire de le remplacer dans toutes les positions...

Page 13: ...adanz 50 Ohm Zwischenfrequenz 10 7 MHz 455 KHz Empfindlichkeit f r erfolgreiches Signal 115 117 dBm Spannungsversorgung 230 Vac Motorleistung 400 W Codespeicher 100 Codierung Dip Schalter Betriebstemp...

Page 14: ...LR PV LV ON 1 2 3 4 5 6 OFF Abb 23 Auswahl der Funktionsmodalit ten Bemerkung Hoher Batterieverbrauch im Handsender da Funkbefehl gehalten werden mu w hrend der gesamten ffnung oder Schlie ung Einstel...

Page 15: ...er Bin rsequenz berschreiben eines eingelernten Handsenders nur Modell 2641 R433P4 Ein verlorener oder defekter Handsender kann direkt durch berschreiben seiner Speicherposition gel scht und durch ein...

Page 16: ...vom inneren angezeigten Herstellungsdatum W hrend solcher Periode wenn das Ger t nicht korrekt wegen eines defekten Bauelements arbeitet wird es beseitigt oder nach Hersteller Entscheidung ersetzt Die...

Reviews: