Receiver type
Superheterodyne
Carrier frequency
433,92 MHz
Demodulation
GFSK
Local Oscillator
VCO / PLL
Input sensitivity
-115 dBm
Local oscillator spurious emissions
< -57 dBm
Input load:
50 Ohm
Power supply:
12 / 24 Vac/dc
Max applicable power
24VA
Current consumption : at rest
9 mA ( @12V or 24V)
with relay excited
26 mA @ 12V
31 mA @ 24V
Relay number
1
Operating modes
Pulse / Delayed
Release delay
1 - 30 Sec.
Contacts
C-NO
Memory capacity
248 user codes
TX security code
Rolling code
128
Max code combination number
2
Operating temperature
-20°/+70°C
Housing protection
IP2X
Overall dimensions (mm)
50 x 32 x 20
2 - TECHNICAL SPECIFICATIONS
ERONE 1 RELAY NANO RECEIVER 128 BIT
1 - DESCRIPTION
Thank you for choosing this product.
You are recommended to read carefully this manual before
installing the product.
1A - Introduction
The receiver type SEL128R433-NN is , designed to control
automatic closing systems and anti-burglar systems, thanks to its
very high security coding system.
The operating frequency is among the European harmonised
frequencies; the product fully complies with the EMC European
Regulations (CE).
The code sent by the transmitter changes at every activation,
avoiding any scanning and copying risk.
A special algorithm allows to keep synchronized transmitter and
receiver.
The receiver has 1 output relay ( with NO contacts, and can be
connected to many types of mechanics ( gate, garage door, rolling
shutters, awnings, anti-burglar appliances, lighting, etc.).
All the receivers of the range can store into the EEPROM a serial
number, a manufacturer key and a synchronism algorithm of more
transmitters.
The programming can be done in self-learning mode by means of
one button.
The housing protection allows indoor installations.
The appliance full complies with the European Directive
2014/53/UE «Red» and the Standard and FCC Part 15.
38,7
50
32
Dimensions
3
3 - LAYOUT AND CONNECTIONS
J1 = CLOSED
MEMO without P1
ENABLED ( 5.2)
MEMO SELECTION
INSTALLATION MANUAL
SEL128R433-NN
Fig. 1
P1
J1
RELAY
K1
BUZZER
+
-
C
NO
ANTENNA
see
Memo selection
4 - OPERATING MODES & DELAY
The relay can operate in PULSE or DELAYED mode. The default
pulse is 1 sec. In delayed mode the release of the relay occurs after
a programmable delay ( 1 - 30 Sec. ) see next paragraph.
During the delay time the reception of a further signal from the
transmitter releases the relay.
J1 = OPEN
MEMO without P1
DISABLED (5.2)
- The equipment must be powered from a device that
provides a safety extra low voltage (SELV) type LPS
( Low Power Source);
- There must be a suitable disconnecting device to the
current drawn by the receiver (90 mA max @ 12Vdc).
!
Power Input
12 - 24 Vac/dc
self-adjusting