Adjustment and Settings
The BDR-510/2 series has been designed for easy installation and set-up. All settings is made
via switches or jumpers. Figure 9 shows where the different switches and jumpers are located:
C4
C5
C7
C12
D2
D4
D5
R3
R4
TP1
TP4
V3
V5
Y19
B1
C1
C2
C3
C8
D1
N4
RS1
R1
R2
R11
R12
R13
S1
6V
12V
TP2
TP3
TP5
V1
SYNC
V2
ERROR
SW1
ON
1 2 3 4 5 6
2
1
Figure 9, Jumper and switch lay-out.
3.1
Address settings (1)
With the BDR-510/2 series it is possible to address up to 64 units on one twisted pair line:
Switch SW1
Description
1
2
3
4
5
6
Address number "0"
ON
ON
ON
ON
ON
ON
Address number "1"
ON
ON
ON
ON
ON
OFF
Address number "2"
ON
ON
ON
ON
OFF
ON
Address number "3"
ON
ON
ON
ON
OFF
OFF
Address number "4"
ON
ON
ON
OFF
ON
ON
Address number "5"
ON
ON
ON
OFF
ON
OFF
Address number "6"
ON
ON
ON
OFF
OFF
ON
Address number "7"
ON
ON
ON
OFF
OFF
OFF
Address number "8"
ON
ON
OFF
ON
ON
ON
Address number "9"
ON
ON
OFF
ON
ON
OFF
Address number "10"
ON
ON
OFF
ON
OFF
ON
Address number "11"
ON
ON
OFF
ON
OFF
OFF
Address number "12"
ON
ON
OFF
OFF
ON
ON
Address number "13"
ON
ON
OFF
OFF
ON
OFF
Address number "14"
ON
ON
OFF
OFF
OFF
ON
Address number "15"
ON
ON
OFF
OFF
OFF
OFF
Address number "16"
ON
OFF
ON
ON
ON
ON
Installation Manual
Page 10
3020-00025