Page 1: ...0 OPERATION INSTRUCTION Wet vacuum cleaner W350P READ ALL INSTRUCTIONS BEFORE USING ...

Page 2: ...ntinue to provide the market with new equipment Notice This instruction does only cover the wet vac type Ermator W350P The vet vacuum cleaner Ermator W350P are developed for cleaning of construction area water cooled drilling machines etc If the wet vac is used for other applications or been used in other ways then explained in this instruction book Ermator will not take any responsibility Before ...

Page 3: ... where explosive gases can occur Large risk for explosions Warning Do not point the suction hose towards body parts when the machine is running Avoid placing your hand or other parts of the body against the suction inlet if the suction hose is not fitted Risk of personal injury Warning Check when lifting the machine that the dust container is empty and that no one is standing under the lifted mach...

Page 4: ...ustable wheels Adjust the wheel setting so as to achieve the best suction effect Adjust the wheels with the knob which is located on the rear side of the nozzle The wheels and rubber strips of the nozzle are replaceable Ensure that the nozzle is kept in good condition After use Switch off the suction apparatus with the switch Remove the plug on the electrical cable from the electrical outlet Do no...

Page 5: ...s Following is parts that should be changed on a regular basis Part no Description No machine 1337019 400 2C C filter 1 pc W350P Spare parts see enclosed spare parts list Warranty All Pullman suction devices and accessories have a 12 month factory warranty for material and manufacturing defects You can extend the warranty to 36 months by returning the attached warranty slip Do not attempt to repai...

Page 6: ... start No current Connect the machine Defect cable Change Defect switch Change Motor stops immediately Wrong fuse Connect to proper fuse Motor runs but no suction Hose not connected Connect the hose Hose blocked Clean the hose Motor runs but poor suction Hole on the hose Change hose Blocked filter Change filter Suction unit loose Adjust Dirt in the hose or Clean the hose and intake intake Defect s...

Page 7: ... POWER 650 W MAX LIFT HEIGHT 9 m MAX SUCTION CAPACITY 290 l min MAX AIRFLOW 200 m h MAX VACUUM 22 kPa HOSE 38 50mm INLET 50mm MAIN FILTER 99 5 Filter surface 0 6m2 SOUND LEVEL 77 dB A DUST COLLECTION SYSTEM 55 l disp bag Disp bag 580x780mm DIMENSION LxWxH 650x600x1020mm WEIGHT 33 kg ...

Page 8: ...var at maskinen W350P Nr No 0600764 0001 xxxx Tillv år Manufact year Baujahr 2006 som omfattas av denna försäkring är i överensstämmelse med standarder included in this declaration follows the provisions of the est conforme aux aux normes suivantes den folgenden Normen entspricht er i overensstemmelse med standarder SS EN 292 1 SS EN 60 204 1 1993 11 30 SS EN 55011 1989 SS EN 50082 1 SS EN 60335 1...

Page 9: ...Revision 0 8 ACCESSORIES W350P ...

Page 10: ...Revision 0 9 W350P ...

Page 11: ...Revision 0 10 W350P ...

Page 12: ...Revision 0 11 W350P ...

Page 13: ..._______ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ...

Page 14: ...Revision 0 13 ...

Reviews: