1:
Motor on
Dust-laden air is then sucked through the inlet valve at high speed via the suction hose. The air is
slowed down by the cyclone and coarse dust particles are separated out, partly by centrifugal force and
partly by gravity. Air and finer particles then pass through the double filter system where separation is
made. The machine is designed for filter cleaning by reverse air pulse.
The separated dust accumulates in the cyclone until the machine is switched off, when it drops through
the bottom flap into the plastic bag.
4. USE
Before use, the user must be trained in handling the machine and the hazardous dust.
Connect the electric plug to an outlet with the correct voltage (see the designation plate).
The filter must be cleaned from time to time. This must be done before changing the plastic bag and
can also be done when the work is complete or when there is poor suction.
Procedure:
Cover the inlet, use attached cover, let the machine build up vacuum for a few seconds
then quickly push down on the key and release it. Repeat the procedure 4-5 times.
Turn of the motor and wait until it stops completely, then uncover the inlet.
If suction remains poor, the filter should be replaced.
Only use original parts.
5. DUST STORAGE SYSTEM
S36 are equipped with Longopac system for effective dust storage. This is a 20 m long plastic
tube that will be divided into plastic bags using the striped attached with the machine. To
mount a new Longopac bag:
Release the belt holding the last bag. Remove the holder. Put in a new Longopac bag, pull out
the inner end upwards. Mount the holder on to the machine and strap the upwards end with
the belt. Pull down to outside end and close it using a stripe.
The machine can be used with original Ermator dust bag for single use.
Only change Longopac or bag after jet pulsing the filter
6. FILTER CHANGE
Risk of dust dispersion - Use of personal safety equipment
Unhealthy dust can be spread during filter change. Accordingly, the user should wear protective
glasses, protective gloves, and a breathing mask conforming to protection class FFP3.
Main filter
Loosen the 3 clamps and remove the top. Take the bag from the new filter.
Lift out the filter and place it gently in a plastic bag. This bag must be properly disposed.
Insert a new filter.
Only original filters may be used.
Hepa Filter
Loosen the two nuts on the filter cap carefully lift the filter into a clean plastic bag, use the bag from
the new filter. This bag must be properly disposed. Insert a new filter in reverse order.
Check the seal when changing filters and change defective seals.
Reload Longopac/change of dust bag
!
2
Revision 0
WARNING
Connect the electric plug to a power outlet with the correct voltage, see the nameplate.