background image

SERVICE MANUAL 

 

SAFETY INSTRUCTIONS AND MAINTENANCE   

 

WARNING: BEFORE SERVICING THIS CHASSIS, READ THE 

X-RAY RADIATION 

PRECAUTION

SAFETY PRECAUTION

AND 

PRODUCT SAFETY NOTICE

INSTRUCTION 

BELOW. 

X-RAY RADIATION PRECAUTION 

1.  The EHT must be checked every time the TV is serviced to ensure that the CRT does not emit 

X-ray radiation as result of excessive EHT voltage. The maximum EHT voltage permissible in any 

operating circumstances must not exceed the rated value. When checking the EHT, use the High 

Voltage Check procedure in this manual using an accurate EHT voltmeter. 

2.  The only source of X-RAY radiation in this TV is the CRT. The TV minimizes X-RAY radiation, 

which ensures safety during normal operation. To prevent X-ray radiation, the replacement CRT 

must be

 

identical to the original fitted as specified in the parts list. 

3.  Some components used in this TV have safety related characteristics preventing the CRT from 

emitting X-ray radiation. For continued safety, replacement component should be made after 

referring the PRODUCT SAFETY NOTICE below. 

4.  Service and adjustment of the TV may result in changes in the nominal EHT voltage of the CRT 

anode. So ensure that the maximum EHT voltage does not exceed the rated value after service 

and adjustment. 

 

SAFETY PRECAUTION 

WARNING: REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY

1.  The TV has a nominal working EHT voltage. Extreme caution should be exercised when working 

on the TV with the back removed.   

1.1  Do not attempt to service this TV if you are not conversant with the precautions and procedures for 

working on high voltage equipment. 

1.2 When handling or working on the CRT, always discharge the anode to the TV chassis before 

removing the anode cap in case of electric shock. 

1.3 The CRT, if broken, will violently expel glass fragments. Use shatterproof goggles and take 

extreme care while handling. 

1.4  Do not hold the CRT by the neck as this is a very dangerous practice. 

2.  It is essential that to maintain the safety of the customer all power cord forms be replaced exactly 

as supplied from factory. 

3.  Voltage exists between the hot and cold ground when the TV is in operation. Install a suitable 

isolating transformer of beyond rated overall power when servicing or connecting any test 

equipment for the sake of safety.   

 

                                                                                  1

 

Summary of Contents for SF21GA63

Page 1: ...COLOR TELEVISION SERVICE MANUAL MODEL NO CHASSIS NO ETA 1U Please read this manual carefully before service SF21GA63...

Page 2: ...CT SAFETY NOTICE 2 SAFETY SYMBOL DESCRIPTION 3 MAINTENANCE 3 ADJUSTMENTS 4 SET UP ADJUSTMENTS 4 CIRCUIT ADJUSTMENTS 7 STRUCTURE AND CHASSIS FUNCTION DESCRIPTION 13 STRUCTURE BLOCK DIAGRAM 13 CHASSIS D...

Page 3: ...ICE below 4 Service and adjustment of the TV may result in changes in the nominal EHT voltage of the CRT anode So ensure that the maximum EHT voltage does not exceed the rated value after service and...

Page 4: ...se characteristics are often passed unnoticed by a visual inspection and the X ray radiation protection afforded by them cannot necessarily be obtained by using replacements rated at higher voltages o...

Page 5: ...ts identified by the VDE marking have special safety related characteristics MAINTENANCE 1 Place the TV set on a stable stand or base that is of adequate size and strength to prevent it from being acc...

Page 6: ...t 1 3 Operate the TV for at least 15 minutes 1 4 Degauss the TV set using a specific degaussing coil 1 5 Set the brightness and contrast to maximum 1 6 Counter clockwise rotate the R B low brightness...

Page 7: ...Adjust two tabs of the 6 pole magnet to superimpose red blue line and green line 2 1 6 Remember red and blue movement Repeat steps 2 1 3 2 1 5 until optimal convergence is obtained 2 2 Circumference...

Page 8: ...en the lamp screw holding the deflection yoke assembly Fig 2 4 pole Magnet Movement 6 pole Magnet Movement Center Convergence by Convergence Magnets Incline the Yoke Up or Down Incline the Yoke Right...

Page 9: ...the TV 1 5 Repeat the above steps until the TV is degaussed completely 2 Confirmation and Adjustment for Voltage Caution B voltage has close relation to high voltage To prevent X ray radiation set B v...

Page 10: ...ng the back cover look for the FBT on the main PCB There should be a FCB on the FBT 4 2 Power on the TV and preheat it for 15 min 4 3 Receive a normal TV signal Rotate knob of the FCB until you get a...

Page 11: ...us data GDET0103 05 Table 3 Function Description for Bus Data Symbol Description Data OSD OSD Horizontal Position 4D OPT Optional Setting B3 RCUT R CUT OFF OPT GCUT G CUT OFF OPT BCUT B CUT OFF OPT GD...

Page 12: ...TS Hight 60Hz difference from HIT OPT VLIN V Linearity 50Hz OPT PAGE6 VLIS V Linearity 60Hz difference from VLIN OPT VSC VS Correction 50Hz OPT VSS VS Correction 60Hz OPT HBOW OPT HPARA OPT UBLACK 0B...

Page 13: ...T 04 STBG S TRAP B G 06 STI S TRAP I 08 STDK S TRAP D K 08 STM S TRAP M 03 SSBG S TRAP HP LP B G 08 SSI S TRAP HP LP I 08 SSDK S TRAP HP LP D K 08 PAGE13 SSM S TRAP HP LP M 09 SYNC 03 SYBBN BB judgeme...

Page 14: ...n 1 Second turn on 1 Bit1 0 NO signal 50Hz 1 NO signal 60Hz 1 Bit2 1 Bit3 Search speed 0 Bit4 0 KEY Turn on 1 POWER Turn on Bit5 FM_band 0 Normal 1Wide 0 Bit6 COLOR 0 NTSC PAL N PAL N 1 NTSC 0 Bit7 0...

Page 15: ...UCTURE AND CHISSIS FUNCTION DESCRIPTION 1 STRUCTUE BLOCK DIAGRAM 13 Audio Amplifier TMP8873 Video Amplifier H OUT V OUT Power Supply Circuit TUNER AVIN AVIN AVOUT IR KEY Structure Block Diagram for ET...

Page 16: ...nd bus control EEPROM AT24C16 for data memory LA78040 for vertical output power amplifying TFA9842AJ for audio power amplifying Thick film IC STR G5653 for power circuit adjustment and control The fol...

Page 17: ...P package The MCU contains 8 bit CPU ROM RAM I O ports timer counters A D converters an on screen display controller remote control interfaces IIC bus interfaces and the Closed Caption decoder The TV...

Page 18: ...g Italic underline function Two 8 bit internal timer counter 2 ch Conform to CCD REGULATION Time base timer watchdog timer Jitter elimination 16 interrupt sources external 5 internal 11 IIC bus interf...

Page 19: ...SERVICE MANUAL 3 Block Diagram 17...

Page 20: ...ble through the IIC bus of the internal connections 2 Power Supply TMPA8873 has some power supplies and GND pins Power supplies related MCU must be applied at the first Power supplies for H VCC and TV...

Page 21: ...SERVICE MANUAL 5 TERMINAL INTERFACE 19...

Page 22: ...SERVICE MANUAL 20...

Page 23: ...SERVICE MANUAL 21...

Page 24: ...SERVICE MANUAL 22...