541N SERIES
Erie Water Treatment Controls – Belgium
Page 22
Troubleshooting
Hard (untreated) water to service
Cause
Solution
1.
Open or defective bypass
1.
Close or verify bypass
2.
Valve in regeneration
2.
Wait until regeneration finishes or advance regeneration to end
3.
Loss of resin
3.
Refer to problem “Loss of resin”
4.
Mixing valve open
4.
Reduce mixing valve opening
5.
Change in raw water hardness
5.
Adjust programming accordingly
6.
Unit fails to regenerate
6.
Refer to problem “Unit fails to regenerate”
7.
Valve fails to draw brine
7.
Refer to problem “Valve fails to draw brine”
8.
Decreasing exchange capacity of resin
8.
Clean or replace resin bed
9.
No salt in brine tank
9.
Add salt
10.
Leak at riser tube
10.
Verify that riser tube is seated correctly and is not cracked
Unit fails to regenerate
Cause
Solution
1.
Faulty electrical supply
1.
Verify electrical service (fuse, transformer,...)
2.
Defective flow meter
2.
Clean and/or replace flow meter
3.
Defective PCB
3.
Replace PCB
4.
Defective drain solenoid
4.
Replace drain solenoid
5.
Body stem assembly switches
continuously
5.
Check minimum operating pressure; refer to Installation “Drain
flow adjuster”
Valve fails to draw brine
Cause
Solution
1.
Low operating pressure
1.
Verify operating pressure; must exceed 1,4 bar
2.
Drain flow adjuster too much closed
2.
Open drain flow adjuster slowly until unit draws brine
3.
Plugged injector and or brine restrictor
3.
Clean injector and or brine restrictor
4.
Backwash solenoid plunger stuck in
open position
4.
Clean or replace plunger and solenoid diaphragm
5.
Plugged injector filter
5.
Clean injector filter
6.
Restricted drain line
6.
Verify drain line for kinks or restrictions
7.
Restricted brine line
7.
Verify brine line for kinks or restrictions
8.
Leak in brine line
8.
Verify brine line and connections for air leakage
9.
Not enough water in brine tank
9.
Refer to problem “Valve fails to refill brine tank”
Summary of Contents for 541N Series
Page 1: ...541N SERIES Technical Manual...
Page 11: ...541N SERIES Erie Water Treatment Controls Belgium Page 9...
Page 23: ...541N SERIES Erie Water Treatment Controls Belgium Page 21...
Page 32: ...541N SERIES Erie Water Treatment Controls Belgium Page 30 Valve body 541N19...
Page 42: ......
Page 43: ......